Foreword
1 Scope
2 Normative references
3 Definitions
4 Limits of supply
5 Rating
      5.1 Rated voltage
      5.2 Number of phases in one enclosure
      5.3 Rated insulation level
      5.4 Rated normal current and temperature rise
      5.5 Rated short-time and peak withstand currents
             and rated duration of short circuit
6 Design and construction requirements
      6.1 Pressure withstand requirements
      6.2 Mechanical forces on cable-terminations
7 Standard dimensions
      7.1 Fluid-filled cable-terminations
      7.2 Dry type cable-terminations
8 Tests
      8.1 General
      8.2 Dielectric type tests
             8.2.1 Dielectric type tests of cable-
                      terminations
             8.2.2 Dielectric type test of cable
                      connection enclosures
      8.3 Tests after cable installation
9 Information to be given with enquiries, tenders
      and orders
10 Rules for transport, storage, erection, operation
      and maintenance
Figure 1 - Fluid-filled cable connection assembly -
           Typical arrangement
Figure 2 - Fluid-filled cable connection assembly -
           Dimensions
Figure 3 - Dry type cable connection assembly -
           Typical arrangements
Figure 4 - Dry type cable connection assembly -
           Dimensions
Figure 5 - Non-symmetrical arrangement for dielectric
           tests of cable terminations

Covers the connection assembly of cables to gas-insulated metal-enclosed switchgear in single- or three-phase arrangements where the cable terminations are fluid-filled and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear.The contents of corrigenda of February 2000 and December 2000 have been included in this copy.

DocumentType
Technical Specification
Pages
31
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
BS 6904:1987 Identical
VDE 0670-802 : DRAFT 1997 Similar to
NEN NPR IEC/TS 60859 : 1999 C1 2000 Identical
BS EN 60958-3:2000 Identical

⚠

A newer version of this standard is available.

View Current Edition
€82.26
Excluding VAT