• IEC TS 62558:2011

    Current The latest, up-to-date edition.

    Ultrasonics - Real-time pulse-echo scanners - Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  23-03-2011

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols
    5 Ambient conditions of measurement with the phantom
    6 Specification of TMM 3D artificial anechoic-cyst phantom
    7 Principle of measurement using the 3D anechoic void phantom
    Annex A (informative) - Description of construction of an
            example phantom and test results
    Annex B (informative) - System description
    Annex C (informative) - Rationale
    Annex D (informative) - Uniformity measurement
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC/TS 62558:2011(E) specifies essential characteristics of a phantom and method for the measurement of void-detectability ratio for medical ultrasound systems and related transducers. It is restricted to the aspect of long-term reproducibility of testing results. Medical diagnostic ultrasound systems and related transducers need periodic testing as the quality of medical decisions based on ultrasonic images may decrease over time due to progressive degradation of essential systems characteristics. The TMM (Tissue Mimicking Material) phantom is intended to be used to measure and to enable documentation of changes in void-detectability ratio in periodic tests over years of use. This technical specification establishes:
    - Important characteristics and requirements for a TMM 3D artificial cyst phantom using anechoic voids
    - A design example of a 3D artificial cyst phantom, the necessary test equipment and use of relevant computer software algorithms.
    This technical specification is currently applicable for linear array transducers. A uniformity test prior to void-detectability ratio (VDR) measurement is recommended.

    General Product Information - (Show below) - (Hide below)

    Committee TC 87
    Development Note Stability Date: 2018. (09/2017)
    Document Type Technical Specification
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD IEC/TS 62736:2016 Ultrasonics. Pulse-echo scanners. Simple methods for periodic testing to verify stability of an imaging system’s elementary performance
    BS EN 61391-1 : 2006 ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE
    I.S. EN 61391-1:2006 ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE
    IEC TS 62736:2016 Ultrasonics - Pulse-echo scanners - Simple methods for periodic testing to verify stability of an imaging system's elementary performance
    IEC 61391-1:2006+AMD1:2017 CSV Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response
    15/30330344 DC : 0 BS EN 61391-1+A1 - ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF POINT-SPREAD FUNCTION RESPONSE
    14/30250927 DC : 0 BS IEC 62736 - ULTRASONICS - PULSE-ECHO SCANNERS - QUALITY CONTROL OF DIAGNOSTIC MEDICAL ULTRASOUND SYSTEMS - SIMPLE METHODS FOR PERIODIC TESTING TO VERIFY STABILITY OF AN IMAGING SYSTEM'S ELEMENTARY PERFORMANCE
    EN 61391-1:2006/A1:2017 ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE (IEC 61391-1:2006/A1:2017)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60050-802:2011 International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics
    IEC 62453-1:2016 Field device tool (FDT) interface specification - Part 1: Overview and guidance
    IEC 61391-1:2006+AMD1:2017 CSV Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response
    IEC 61391-2:2010 Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
    IEC 60761-1:2002 Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 1: General requirements
    IEC 62270:2013 Guide for computer-based control for hydroelectric power plant automation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective