IEC TS 62743:2012
Current
The latest, up-to-date edition.
Radiation protection instrumentation - Electronic counting dosemeters for pulsed fields of ionizing radiation
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
19-09-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions, abbreviations
and symbols, quantities and units
4 General test procedure
5 General requirements
6 Radiation detection requirements
7 Environmental requirements
8 Mechanical requirements
9 Electromagnetic requirements
10 Documentation
Annex A (informative) - Parameter values for typical
workplaces where pulsed radiation occurs
Annex B (informative) Parameters characterizing the
pulsed radiation field
Bibliography
IEC/TS 62743:2012(E) applies to all types of counting dosemeters, irrespective of the measuring quantity and the type of radiation intended to be measured. It ensures that a single radiation pulse can be correctly measured even if the dosemeter is in the internal state relevant for measuring background or environmental radiation. The characteristics of the dosemeter for repeated pulses is expected to be better than for one single radiation pulse with the same parameters but worse than for continuous radiation, i.e., in between of the characteristics for these two extreme conditions. Considers the pulsation of the radiation field as an additional influence quantity like particle energy and direction of radiation incidence. Therefore, the tests described are additional to all the tests in the respective standards.
Committee |
TC 45/SC 45B
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Technical Specification
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NEN NPR IEC/TS 62743 : 2012 | Identical |
VDE V 0492-4-1 : 2013 | Identical |
DIN IEC/TS 62743 : 2013 | Identical |
PD IEC/TS 62743:2012 | Identical |
I.S. EN ISO 15382:2017 | RADIOLOGICAL PROTECTION - PROCEDURES FOR MONITORING THE DOSE TO THE LENS OF THE EYE, THE SKIN AND THE EXTREMITIES (ISO 15382:2015) |
ISO 15382:2015 | Radiological protection Procedures for monitoring the dose to the lens of the eye, the skin and the extremities |
EN ISO 15382:2017 | Radiological protection - Procedures for monitoring the dose to the lens of the eye, the skin and the extremities (ISO 15382:2015) |
BS EN ISO 15382:2017 | Radiological protection. Procedures for monitoring the dose to the lens of the eye, the skin and the extremities |
ISO/TS 18090-1:2015 | Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation |
IEC 60846-1:2009 | Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors |
IEC 61526:2010 | Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.