IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

04-12-2014

€185.10
Excluding VAT

1 Overview
2 Normative references
3 Definitions
4 The nature of PD in machine windings
5 Overview of PD detection methods
6 Electrical pulse and RF radiation sensing systems
7 Electrical pulse and RIV measuring instruments
8 Pulse propagation in windings and calibration issues
9 On-line versus off-line testing
10 Test procedures
11 Interpretation of PD test results
Annex A (informative) - Bibliography
Annex B (normative) - Coupling capacitor type tests
        and routine tests
Annex C (informative) - Typical PD pulse-phase patterns
        (examples)
Annex D (informative) - Typical time-frequency
        classification map
Annex E (informative) - Synchronous three channel
        multi-spectral analyzer
Annex F (informative) - Electrical pulse and RF radiation
        sensing systems in limited use
Annex G (informative) - Interpretive methods in limited
        use

This guide discusses both on-line and off-line partial discharge (PD) measurements on complete windings of any type, as well as measurements on individual form-wound coils and bars.

Committee
Electric Machinery
DevelopmentNote
Supersedes IEEE DRAFT 1434. (09/2000)
DocumentType
Standard
ISBN
978-0-7381-9352-6
Pages
89
PublisherName
Institute of Electrical & Electronics Engineers
Status
Current
Supersedes

IEEE 3004.8-2016 IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems
IEEE 1665 : 2009 GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE
ASTM D 3382 : 2013 : REDLINE Standard Test Methods for Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques
(INACTIVE RECORD)IEEE C50.12 : 2005 SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE
IEEE 1799-2012 IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings
IEEE DRAFT C50.12 : D10 2004 SALIENT-POLE 50 AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE
IEEE DRAFT 434 : D10 2006 FUNCTIONAL EVALUATION OF INSULATION SYSTEMS FOR AC ELECTRIC MACHINES RATED 2300 V AND ABOVE
12/30243450 DC : DRAFT FEB 2012 BS ISO 20958-1 - CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - ELECTRICAL SIGNATURE ANALYSIS - PART 1: THREE-PHASE INDUCTION MOTORS
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
IEEE C50.13 : 2014 CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE
ISO 20958:2013 Condition monitoring and diagnostics of machine systems — Electrical signature analysis of three-phase induction motors
IEEE DRAFT 67 : D5 2005 GUIDE FOR THE OPERATION AND MAINTENANCE OF TURBINE GENERATORS
IEEE 434-2006 IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above
ASTM D 1868 : 2013 : REDLINE Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems
IEEE 1415 : 2006 INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS
IEEE 1129-2014 IEEE Guide for Online Monitoring of Large Synchronous Generators (10 MVA and Above)
IEEE 115-2009 REDLINE IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis
IEC TS 60034-27:2006 Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
IEC 60034-27-1:2017 Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation
CLC/TS 60034-27:2011 Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
S.R. CLC/TS 60034-27:2011 ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES
05/30128254 DC : DRAFT JAN 2005 IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY
BS ISO 20958:2013 Condition monitoring and diagnostics of machine systems. Electrical signature analysis of three-phase induction motors
DD CLC/TS 60034-27:2011 Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
IEEE 45.6-2016 IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing
IEEE 1310-2012 REDLINE IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines
IEEE 1349-2011 REDLINE IEEE Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations
IEEE 56-2016 IEEE Guide for Insulation Maintenance of Electric Machines
IEEE 115-2019 IEEE Guide for Test Procedures for Synchronous Machines Including Acceptance and Performance Testing and Parameter Determination for Dynamic Analysis
IEEE 2465-2023 IEEE Trial-Use Recommended Practice for Pulse-Type Partial Discharge Measurements on Individual Stator Coils and Bars

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC TS 60034-27:2006 Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
NEMA 107:2016 Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
IEC TS 61934:2011 Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses
IEEE 510-1983 IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing
IEC 60505:2011 Evaluation and qualification of electrical insulation systems
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
ASTM D 2303 : 2013 Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials
ASTM D 3382 : 2013 : REDLINE Standard Test Methods for Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques
IEEE 433-2009 REDLINE IEEE Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage at Very Low Frequency
IEEE C37.20.2-1999 IEEE Standard for Metal-Clad Switchgear
IEEE 1799-2012 IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings
IEC TS 60034-27-2:2012 Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation of rotating electrical machines
ASTM D 1868 : 2013 : REDLINE Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
IEEE 286-2000 IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation