IEEE 1615-2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Recommended Practice for Network Communication in Electric Power Substations
11-11-2019
English
08-08-2007
1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Acronyms and abbreviations
4 Electric utility information system architecture
4.1 Traditional serial-communication architecture
4.2 Networked communication architecture
4.3 Moving to a network-based system
5 Internet protocol suite (IPS) and services
5.1 IP layers
5.2 IP Addressing
5.3 Recommendations for utility networks
6 Data classification and security for IPS networks
6.1 Types and uses of data
6.2 Security issues and recommendations
7 System level requirements in substation networks
7.1 Performance requirements of a substation network
7.2 Time synchronization
7.3 Substation noise sources
8 Network management tools and practices for an electric utility
information system
8.1 Vendor-specific network devices
8.2 Network management in the electric utility information
system
8.3 Tools
9 Media and device alternatives for the substation network
9.1 Media
9.2 Network devices
10 Substation LAN requirements
10.1 Port speed and fiber-optic interface
10.2 Full duplex operation and collision-free environment
10.3 Priority queuing
10.4 Virtual LAN support
10.5 Loss-of-link management
10.6 Rapid-spanning tree algorithm support
10.7 Flow control
10.8 Multicast propagation control
10.9 Remote monitoring, port mirroring, and diagnostic support
10.10 Environmental hardening
10.11 MAC filtering and port lockout
10.12 Summary recommendations to support real-time protection
over Ethernet
Annex A (informative) Security issues and awareness
A.1 Source of threats to the electric power system
A.2 Targets of attack in the electric utility network
A.3 Common cyber-attack techniques
A.4 Techniques to address threats to the electric utility
network
Annex B (informative) DNP3 - IP networking
B.1 DNP3 protocol overview
B.2 History of DNP3
B.3 Protocol features
B.4 Features of the DNP3 protocol pertinent to this
recommended practice, IEEE Std 1615-2007
B.5 DNP3 definition documents
Annex C (informative) IEC 60870-5-104
C.1 Background/history
C.2 Functionality in a network environment
C.3 Features of IEC 60870-5-104 pertinent to this
recommended practice, IEEE Std 1615-2007
C.4 IEC 60870-5-104 definition documents
Annex D (informative) IEC 61850
D.1 Overview and history of IEC 61850
D.2 The information model according to IEC 61850
D.3 Information exchange
D.4 Configuration management
D.5 Features of IEC 61850 pertinent to this recommended
practice, IEEE Std 1615-2007
Annex E (informative) Bibliography
Describes a recommended practice for communication and interoperation of devices connected on an electric power substation Internet protocol (IP) network.
Committee |
Power System Communications and Cybersecurity
|
DevelopmentNote |
Supersedes IEEE DRAFT 1615. (10/2007)
|
DocumentType |
Standard
|
Pages |
246
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
IEEE C37.242-2013 | IEEE Guide for Synchronization, Calibration, Testing, and Installation of Phasor Measurement Units (PMUs) for Power System Protection and Control |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
12/30260040 DC : 0 | BS EN 62270 - GUIDE FOR COMPUTER-BASED CONTROL FOR HYDROELECTRIC POWER PLANT AUTOMATION |
IEC 62270:2013 | Guide for computer-based control for hydroelectric power plant automation |
IEEE C37.233 : 2009 | GUIDE FOR POWER SYSTEM PROTECTION TESTING |
IEEE/IEC 1249-2013 | IEC/IEEE Guide for Computer-based Control for Hydroelectric Power Plant Automation |
IEEE 2030.100-2017 | IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System |
IEEE 789-2013 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments |
IEEE C37.1-2007 REDLINE | IEEE Standard for SCADA and Automation Systems |
IEEE 1590-2009 | IEEE Recommended Practice for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Using Optical Fiber Systems |
IEEE 802.3-2005 | IEEE Standard for Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications |
IEEE 1646 : 2004 | COMMUNICATION DELIVERY TIME PERFORMANCE REQUIREMENTS FOR ELECTRIC POWER SUBSTATION AUTOMATION |
TIA/EIA 568 SET : C2009 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD SET |
IEEE 1590-2003 | IEEE Recommended Practice for the Electrical Protection of Optical Fiber Communication Facilities Serving, or Connected to, Electrical Supply Locations |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
IEC 60870-5-104:2006+AMD1:2016 CSV | Telecontrol equipment and systems - Part 5-104: Transmission protocols - Network access for IEC 60870-5-101 using standardtransport profiles |
IEEE 802.1Q-2014 | IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks |
IEEE 802.11-2016 | IEEE Standard for Information technology--Telecommunications and information exchange between systems Local and metropolitan area networks--Specific requirements - Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications |
IEEE 802.1D-2004 | IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges |
IEEE 802.1Q-2005 | IEEE Standard for Local and Metropolitan Area Networks---Virtual Bridged Local Area Networks |
IEEE C37.90.3-2001 | IEEE Standard Electrostatic Discharge Tests for Protective Relays |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEEE C37.90.2:2004 | WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS |
IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
IEEE 1588-2008 REDLINE | IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems |
IEEE 1613-2003 | IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations |
IEEE/IEC C37.111-2013 REDLINE | IEEE/IEC International Standard - Measuring relays and protection equipment - Part 24: Common format for transient data exchange (COMTRADE) for power systems |
IEEE C37.115-2003 | IEEE Standard Test Method for Use in the Evaluation of Message Communications Between Intelligent Electronic Devices in an Integrated Substation Protection, Control and Data Acquisition System |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.