1 Overview
2 Normative references
3 Definitions, acronyms, and abbreviations
4 Description of the IEMI threat
5 Types of equipment and systems to be protected
6 Protection methods
7 Monitors and alarms
8 Recommended protection approach
9 Test methods
Annex A (informative) - Bibliography
This recommended practice establishes appropriate electromagnetic (EM) threat levels, protection methods, monitoring techniques, and test techniques for specific classes of computer equipment.
| Committee |
Standards Development Committee
|
| DocumentType |
Standard
|
| ISBN |
978-0-7381-9490-5
|
| Pages |
39
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| IEC TR 62351-13:2016 | Power systems management and associated information exchange - Data and communications security - Part 13: Guidelines on security topics to be covered in standards and specifications |
| IEC TR 61000-1-5:2004 | Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems |
| IEEE 299-2006 | IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures |
| IEC 61000-4-25:2001+AMD1:2012 CSV | Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems |
| IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
| IEC 61000-6-6:2003 | Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment |
| IEEE 299.1-2013 | IEEE Standard Method for Measuring the Shielding Effectiveness of Enclosures and Boxes Having all Dimensions between 0.1 m and 2 m |
| IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
| IEC 61000-4-23:2016 | Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances |
| IEC 61000-2-13:2005 | Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted |