• IEEE 400-2012 REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above

    Available format(s):  PDF

    Superseded date:  17-11-2023

    Language(s):  English

    Published date:  05-06-2012

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. Definitions, acronyms, and abbreviations
    4. Safety awareness
    5. General considerations for field-testing of cable
       systems
    6. Field testing methods
    7. Applicability of testing methods
    Annex A (informative) - Bibliography
    Annex B (informative) - Test voltage levels and durations
    Annex C (informative) - Information on applicability of
            field testing methods from CDFI

    Abstract - (Show below) - (Hide below)

    Presents an overview of the various test methods available for evaluating the insulation of shielded cable systems in the field, and to assist cable owners in selecting one or more appropriate tests for a specific application.

    General Product Information - (Show below) - (Hide below)

    Committee Insulated Conductors
    Development Note Supersedes IEEE DRAFT 400. (09/2004) Also included in IEEE 400 Set (CD-ROM) dated 28/11/2012 with IEEE 400.1, IEEE 400.2 and IEEE 400.3. Also included in IEEE 400 Series dated 05/10//2013 with IEEE 400.1, IEEE 400.2 and IEEE 400.3. (10/2013)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
    IEEE 902-1998 IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book)
    IEEE 844-2000 IEEE Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and Vessels
    IEEE 1242-1999 IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants
    IEEE DRAFT 1511 : D6.0 MAY 2000 DRAFT GUIDE FOR INVESTIGATING AND ANALYZING POWER CABLE, JOINT, AND TERMINATION FAILURES ON SYSTEMS RATED 5 KV THROUGH 46 KV
    IEEE 1234-2007 IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems
    IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
    NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
    IEEE DRAFT 1147 : D8 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
    UFC 3-550-07 : 2017 UNIFIED FACILITIES CRITERIA - OPERATION AND MAINTENANCE (O&M;): EXTERIOR POWER DISTRIBUTION SYSTEMS
    TM 5-811-1 : V19950228 ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION
    NFPA 70B:2023 Standard for Electrical Equipment Maintenance
    CSA C68.10 : 2014 SHIELDED POWER CABLE FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS, 5-46 KV
    NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    IEEE DRAFT 525 : D15 2006 DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS
    CSA M421 : 2011 USE OF ELECTRICITY IN MINES
    IEEE DRAFT 1215 : D13 2001 DRAFT GUIDE FOR THE APPLICATION OF SEPARABLE INSULATED CONNECTORS
    API SPEC 17E : 2017 SPECIFICATION FOR SUBSEA UMBILICALS
    IEEE DRAFT 400.2 : D5 MAR 2000 DRAFT GUIDE FOR FIELD TESTING OF SHIELDED POWER CABLE SYSTEMS USING VERY LOW FREQUENCY (VLF)
    IEEE 3007.2 : 2010 This recommended practice covers the maintenance of industrial and commercial power systems.
    IEEE 1017-2013 IEEE Recommended Practice for Field Testing Electric Submersible Pump Cable
    IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
    CSA M421 : 2011 : R2016 USE OF ELECTRICITY IN MINES
    IEEE 3001.2-2017 IEEE Recommended Practice for Evaluating the Electrical Service Requirements of Industrial and Commercial Power Systems
    IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
    IEEE 690-2004 IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations
    IEEE 1205-2014 IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities
    IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
    IEEE 1185-2010 IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities
    IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
    IEEE 400.4-2015 IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
    IEEE 45.6-2016 IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing
    IEEE 400.2-2013 REDLINE IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)
    IEEE 1215-2013 REDLINE IEEE Guide for the Application of Separable Insulated Connectors
    IEEE 1234-2019 REDLINE IEEE Guide for Fault-Locating Techniques on Shielded Power Cable Systems

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
    IEEE 1366-2012 IEEE Guide for Electric Power Distribution Reliability Indices
    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    NEMA WC 74 : 2012 5-46 KV SHIELDED POWER CABLE FOR USE IN THE TRANSMISSION AND DISTRIBUTION OF ELECTRIC ENERGY
    IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
    IEEE 4-1995 IEEE Standard Techniques for High-Voltage Testing
    IEEE 386-2016 REDLINE IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV
    IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) - Test methods and requirements
    IEEE 400.1-2007 IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage
    NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    IEC 60885-3:2015 RLV Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
    IEEE 400.2-2013 REDLINE IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)
    IEEE 1234-2007 IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems
    IEEE 510-1983 IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE 1617:2007 DETECTION, MITIGATION, AND CONTROL OF CONCENTRIC NEUTRAL CORROSION IN MEDIUM-VOLTAGE UNDERGROUND CABLES
    ICEA S 94 649 : 2013 CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV
    NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
    IEC 60060-3:1976 High-voltage test techniques - Part 3: Measuring devices
    IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
    IEEE 404-2012 IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 62067 : 2.0EN+(REDLINE+VERSION) POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 150 KV (U[M] = 170 KV) UP TO 500 KV (U[M] = 550 KV) - TEST METHODS AND REQUIREMENTS
    IEC 60885-2:1987 Electrical test methods for electric cables. Part 2: Partial discharge tests
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective