IEEE 802.3ab-1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PHYSICAL LAYER PARAMETERS AND SPECIFICATIONS FOR 1000 MB/S OPERATION OVER 4-PAIR OF CATEGORY 5 BALANCED COPPER CABLING, TYPE 1000BASE-T
Hardcopy , PDF
21-12-2001
English
01-01-1999
REVISIONS TO IEEE Std 802.3, 1998 Edition AS
SUPPLEMENTED BY IEEE 802.3ac-1998
1. (Changes to) Introduction
1.3(Changes to) Normative references
1.4(Changes to) Definitions
1.5(Changes to) Abbreviations
22. (Changes to) Reconciliation Sublayer (RS)
and Media Independent Interface (MII)
28. (Changes to) Physical Layer link signalling for Mb/s
and 100 Mb/s Auto-Negotiation on twisted pair
30. (Changes to) 10 Mb/s, 100 Mb/s, and 1000 Mb/s
Management
32. (Changes to)Physical Coding Sublayer (PCS), Physical
Medium Attachment (PMA) sublayer and baseband medium,
type 100BASE-T2
34. (Changes to) Introduction to 1000 Mb/s baseband network
42. (Changes to) System considerations for multisegment
1000 Mb/s networks
ANNEXES
(Changes to) Annex A (informative) Additional reference material
(Changes to) Annex 28B (normative) IEEE 802.3 Selector Base
Page definition
(Changes to) Annex 28C (normative) Next Page Message Code Field
definitions
(Changes to) Annex 28D (normative) Description of extensions to
Clause 28 and associated annexes
(Changes to) Annex 30B (normative) GDMO and ASN.1 definitions
management
40. Physical Coding Sublayer (PCS), Physical Medium
Attachment (PMA) sublayer and baseband medium, type
1000BASE-T
40.1 Overview
40.1.1 Objectives
40.1.2 Relationship of 1000BASE-T to other standards
40.1.3 Operation of 1000BASE-T
40.1.4 Signalling
40.1.5 Inter-sublayer interfaces
40.1.6 Conventions in this clause
40.2 1000BASE-T Service Primitives and Interfaces
40.2.1 Technology-Dependent Interface
40.2.2 PMA Service Interface
40.2.3 PMA_TXMODE.indicate
40.2.4 PMA_CONFIG.indicate
40.2.5 PMA_UNITDATA.request
40.2.6 PMA_UNITDATA.indicate
40.2.7 PMA_SCRSTATUS.request
40.2.8 PMA_RXSTATUS.request
40.2.9 PMA_REMRXSTATUS.request
40.2.10 PMA_RESET.indicate
40.3 Physical Coding Sublayer (PCS)
40.3.1 PCS functions
40.3.2 Stream structure
40.3.3 State variables
40.3.4 State diagrams
40.4 Physical Medium Attachment (PMA) sublayer
40.4.1 PMA functional specifications
40.4.2 PMA functions
40.4.3 MDI
40.4.4 Automatic MDI/MDI-X Configuration
40.4.5 State variables
40.4.6 State Diagrams
40.5 Management interface
40.5.1 Support for Auto-Negotiation
40.5.2 MASTER-SLAVE configuration resolution
40.6 PMA electrical specifications
40.6.1 PMA-to-MDI interface tests
40.7 Link segment characteristics
40.7.1 Cabling system characteristics
40.7.2 Link transmission parameters
40.7.3 Coupling parameters
40.7.4 Delay
40.7.5 Noise environment
40.8 MDI specification
40.8.1 MDI connectors
40.8.2 Crossover function
40.8.3 MDI electrical specifications
40.9 Environmental specifications
40.9.1 General safety
40.9.2 Network safety
40.9.3 Environment
40.10 PHY labelling
40.11 Delay constraints
40.11.1 MDI to GMII delay constraints
40.11.2 DTE delay constraints (half duplex only)
40.11.3 Carrier de-assertion/assertion constraint
(half duplex mode)
40.12 Protocol implementation conformance statement
(PICS) proforma for Clause 40 - Physical
coding sublayer (PCS), physical medium
attachment (PMA) sublayer and baseband
medium, type 1000BASE-T
40.12.1 Identification
40.12.2 Major capabilities/options
40.12.3 Clause conventions
40.12.4 Physical Coding Sublayer (PCS)
40.12.5 Physical Medium Attachment (PMA)
40.12.6 Management interface
40.12.7 PMA Electrical Specifications
40.12.8 Characteristics of the link segment
40.12.9 MDI requirements
40.12.10 General safety and environmental requirements
40.12.11 Timing requirements
Annex 40A (informative) Additional cabling design guidelines
Annex 40B (informative) Description of cable clamp
Annex 40C (informative) Add-on interface for additional Next
Pages
Covers Type 1000BASE-T PCS, type 1000BASE-T PMA sublayer, and type 1000BASE-T Medium Dependent Interface (MDI). This supplement specifies fully functional, electrical and mechanical specifications for the type 1000BASE-T PCS, PMA, and MDI.
DevelopmentNote |
SUPERSEDES IEEE DRAFT 802.3AB
|
DocumentType |
Standard
|
Pages |
140
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
SAE AS 6135: 2012 | INTERFACE STANDARD, AIRBORNE EO/IR SYSTEMS, DATA |
EN 61158-4-17:2008 | Industrial communication networks - Fieldbus specifications - Part 4-17: Data-link layer protocol specification - Type 17 elements |
DEFSTAN 23-09/2(2011) : 2011 | GENERIC VEHICLE ARCHITECTURE (GVA) |
IEEE 802.5v-2001 | IEEE Standard for Information Technology-Telecommunications and information exchange between systems-Local and metropolitan area networks-Part 5: Token Ring access method and physical layer specifications-Amendment 5: Gigabit Token Ring Operation |
SAE AS 6165 : 2012 | INTERFACE STANDARD, AIRBORNE EO/IR SYSTEMS, MAINTENANCE AND TEST |
DIN EN 61158-4-17:2008-09 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-17: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 17 ELEMENTS |
BS EN 61158-4-17:2008 | Industrial communication networks. Fieldbus specifications Data-link layer protocol specification. Type 17 elements |
I.S. EN 61158-4-17:2008 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-17: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 17 ELEMENTS |
IEC 61158-4-17:2007 | Industrial communication networks - Fieldbus specifications - Part 4-17: Data-link layer protocol specification - Type 17 elements |
09/30198396 DC : DRAFT JAN 2009 | BS EN 61784-2 - INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 2: ADDITIONAL FIELDBUS PROFILES FOR REAL-TIME NETWORKS BASED ON ISO/IEC 8802-3 |
CEI EN 61158-4-17 : 2008 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-17: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 17 ELEMENTS |
TS 105 174-7-1 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); BROADBAND DEPLOYMENT AND ENERGY MANAGEMENT; PART 7: DIGITAL MULTISERVICE CITIES; SUB-PART 1: MULTISERVICE STREET FURNITURES |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.