IEEE/ANSI N323B-2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
American National Standard for Radiation Protection Instrumentation Test and Calibration, Portable Survey Instrumentation for Near Background Operation
20-06-2014
English
06-02-2004
1 Scope
2 Definitions
3 General requirements
3.1 The calibration process
3.2 Initial acceptance testing
3.3 Instrument calibration
3.4 Field use
3.5 Recalibration
3.6 Calibration frequency
4 Performance requirements
4.1 General
4.2 Electronic and mechanical effects
4.3 Radiation response
4.4 Interfering response
4.5 Environmental response
5 Calibration facility requirements
5.1 Calibration standards
5.2 Calibration assemblies
5.3 Maintenance of standards
5.4 Check sources
5.5 Calibration source quality
5.6 Calibration facility
6 Calibration protocol requirements
6.1 Dose and dose-rate measuring instruments
6.2 Surface contamination measurement instruments
7 Records
7.1 Instrument information
7.2 Facility documentation
Annex A (informative) Tests performed with variation of
influence quantities
Annex B (informative) Bibliography
Ascertains minimum acceptance performance requirements for portable radiation protection instruments used for detection and measurement of ionizing radiation fields or levels of radioactive surface contamination that are near background.
DevelopmentNote |
Redesignated as ANSI N323AB. (06/2014)
|
DocumentType |
Standard
|
Pages |
29
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
IEEE/ANSI N42.35-2006 | American National Standard Evaluation and Performance of Radiation Detection Portal Monitors for Use in Homeland Security |
IEEE/ANSI N42.48-2008 | American National Standard Performance Requirements for Spectroscopic Personal Radiation Detectors (SPRDs) for Homeland Security |
IEEE/ANSI N42.33-2006 | American National Standard for Portable Radiation Detection Instrumentation for Homeland Security |
IEEE/ANSI N42.34-2006 | American National Standard Performance Criteria for Hand-held Instruments for the Detection and Identification of Radionuclides |
ISO 7503-2:2016 | Measurement of radioactivity - Measurement and evaluation of surface contamination Part 2: Test method using wipe-test samples |
IEEE/ANSI N323A-1997 | American National Standard Radiation Protection Instrumentation Test and Calibration, Portable Survey Instruments |
ISO 6980:1996 | Reference beta radiations for calibrating dosemeters and dose-rate meters and for determining their response as a function of beta-radiation energy |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
ISO 11929-1:2000 | Determination of the detection limit and decision threshold for ionizing radiation measurements Part 1: Fundamentals and application to counting measurements without the influence of sample treatment |
IEEE/ANSI N42.17C-1989 | American National Standard Performance Specifications for Health Physics Instrumentation. Portable Instrumentation for Use in Extreme Environmental Conditions |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
CFR 40(PTS190-259) : JUL 2017 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
ISO 7503-1:2016 | Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles |
ASTM E 1893 : 2015 : REDLINE | Standard Guide for Selection and Use of Portable Radiological Survey Instruments for Performing In Situ Radiological Assessments to Support Unrestricted Release from Further Regulatory Controls |
ANSI N13.6 : 2010 | PRACTICE FOR OCCUPATIONAL RADIATION EXPOSURE RECORDS SYSTEMS |
ISO 8769:2016 | Reference sources Calibration of surface contamination monitors Alpha-, beta- and photon emitters |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
ANSI N13.12 : 2013 | SURFACE AND VOLUME RADIOACTIVITY STANDARDS FOR CLEARANCE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.