• There are no items in your cart

IEEE C37.122.6-2013 REDLINE

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

IEEE Recommended Practice for the Interface of New Gas-Insulated Equipment in Existing Gas-Insulated Substations Rated above 52 kV

Available format(s)

PDF

Withdrawn date

21-03-2024

Language(s)

English

Published date

31-01-2014

€108.54
Excluding VAT

1 Scope
2 Normative references
3 Definitions
4 General
5 Specific requirements during initial stage
  of GIS project
6 Specific requirements during extension
  GIS project
7 Recommended practice for GIS interface
8 Responsibility
Annex A (informative) - Standard GIS interface
        for extensions anticipated from initial
        stage
Annex B (informative) - GIS interface for extensions
        not anticipated from initial stage
Annex C (informative) - Bibliography

This document gives the recommended practices for designing and installing the interfaces between existing gas-insulated substation (GIS) equipment and new GIS equipment that is added at a later date and may be of different design and of different manufacturer.

Committee
Substations
DevelopmentNote
Supersedes IEEE 1416. (02/2014)
DocumentType
Standard
ISBN
978-0-7381-8876-8
Pages
34
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
Supersedes

IEEE C37.122.4-2016 IEEE Guide for Application and User Guide for Gas-Insulated Transmission Lines, Rated 72.5 kV and Above
IEEE C37.122.1-2014 IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
IEEE C37.122-2021 IEEE Standard for High-Voltage Gas-Insulated Substations Rated Above 52 kV

IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEEE C37.122.1-2014 IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
ASTM D 2472 : 2015 : REDLINE Standard Specification for Sulfur Hexafluoride
IEEE C37.123-1996 IEEE Guide to Specifications for Gas-Insulated, Electric Power Substation Equipment
IEEE C37.122-2010 IEEE Standard for High Voltage Gas-Insulated Substations Rated Above 52 kV
IEEE C37.122.1-1993 IEEE Guide for Gas-Insulated Substations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.