IEEE C37.71-2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Standard for Three-Phase Manually Operated Subsurface and Vault Load-Interrupting Switches for Alternating-Current Systems
26-09-2003
English
09-07-2001
1 Scope
2 References
3 Definitions
4 Service conditions
4.1 Usual service conditions
4.2 Unusual service conditions
5 Ratings and test requirements
5.1 Rating information
5.2 Voltage ratings and related test requirements
5.3 Current test values
6 Design tests
6.1 General
6.2 Interrupting current tests
6.3 Short-time current tests
6.4 Insulation (dielectric) tests
6.5 Continuous current test
6.6 Mechanical operation test
6.7 Partial discharge (corona) level test
6.8 DC withstand test
6.9 Pressure tests
7 Production tests
7.1 Circuit resistance test
7.2 Sixty hertz withstand test
7.3 Leak test
7.4 Operating assurance tests
7.5 Partial discharge (corona) level tests
8 Conformance tests
8.1 Temperature measurements
8.2 Impulse withstand tests
8.3 Loop current requirement
9 Construction requirements
9.1 Grounding provision
9.2 Manual operation provisions
9.3 Position indicators
9.4 Insulating medium quantity indicators
9.5 Drain and replacement provisions
9.6 Sampling and addition provisions
9.7 Tank construction
9.8 Terminations
9.9 Bushing designation
9.10 Nameplate
9.11 User identification plate
10 Shipping requirements
Covers three-phase, group operated, 60 Hz, subsurface, load interrupting switches with maximum ratings 600 A and 38 kV, using separable insulated connectors.
Committee |
Switchgear
|
DevelopmentNote |
Supersedes IEEE DRAFT C37.71 (02/2005)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE C37.34-1994 | IEEE Standard Test Code for High-Voltage Air Switches |
IEEE DRAFT C37.20.4 : 2001 | DRAFT STANDARD FOR INDOOR AC SWITCHES RATED ABOVE 1KV THROUGH 38KV FOR USE IN METAL-ENCLOSED SWITCHGEAR |
IEEE C57.12.32-2002 | IEEE Standard for Submersible Equipment - Enclosure Integrity |
IEEE C37.37-1996 | IEEE Loading Guide for AC High-Voltage Air Switches (in Excess of 1000 V) |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
ANSI C37.85 : 1989 | ALTERNATING-CURRENT HIGH-VOLTAGE POWER VACUUM INTERRUPTERS - SAFETY REQUIREMENTS FOR X-RADIATION LIMITS |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.