• IEEE DRAFT C37.60 : D10 SEP 2000

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    DRAFT STANDARD REQUIREMENTS FOR OVERHEAD, PAD MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR AC SYSTEMS

    Available format(s): 

    Superseded date:  11-08-2003

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Institute of Electrical & Electronics Engineers

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 References
    3 Definitions
    4 Service Conditions
       4.1 Usual Service Conditions
       4.2 Unusual Service Conditions
    5 Rating
       5.2 Rated Maximum Voltage
       5.3 Rated Frequency
       5.4 Rated Continuous Current
       5.5 Rated Minimum Tripping Current
           (for Series-Trip Reclosers)
       5.6 Rated Symmetrical Interrupting Current
       5.7 Rated Symmetrical Making Current
       5.8 Rated Impulse Withstand Voltage
       5.9 Rated Control Voltage and Ranges
    6 Design Tests
       6.1 General
       6.2 Insulation (Dielectric Tests)
       6.3 Interruption Tests
       6.4 Making Current Tests
       6.5 Minimum Tripping Current Tests
       6.6 Radio Influence Voltage Tests (RIV)
       6.7 Surge Current Test; Series Coil Reclosers
       6.8 Temperature Rise Test
       6.9 Time-Current Tests
    7 Production Tests
       7.1 Reclosing and Overcurrent Trip Calibration
       7.2 Control, Secondary Wiring and Accessory
           Devices Check Tests
       7.3 Dielectric Withstand Test; One Minute
           Dry Low Frequency
       7.4 Mechanical Operations Tests
       7.5 Water Leak Test
    8 Construction Requirements
       8.1 Tank Construction: Submersible or Dry
           Vault Reclosers
       8.2 Grounding Provisions
       8.3 Insulating Medium Quantity Indicators
       8.4 Oil Sampling Provision (Submersible Reclosers)
       8.5 Manual Operating Provision
       8.6 Position Indicator
       8.7 Nameplate Markings
       8.8 Stored Energy Mechanism Charge Indicator
       8.9 Enclosure Integrity
       Annex A: X/R Ratios
       Annex B: Altitude Correction Factors
       Annex C: Bibliography

    Abstract - (Show below) - (Hide below)

    Applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Document Type Draft
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective