ISA 12.02.01 : 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONES 0, 1 & 2 HAZARDOUS (CLASSIFIED) LOCATIONS - INTRINSIC SAFETY
26-11-2024
01-01-2002
Foreword
1 Scope
2 Normative References
3 Definitions
4 Grouping and classification of intrinsically safe
apparatus and associated apparatus
5 Categories of electrical apparatus
5.1 General
5.2 Category "ia"
5.3 Category "ib"
5.4 Simple apparatus
6 Apparatus construction
6.1 Enclosures
6.2 Wiring and small component temperatures
6.3 Facilities for connection of external circuits
6.4 Separation distances
6.5 Protection against polarity reversal
6.6 Earth (Ground) conductors, connections, and terminals
6.7 Encapsulation used for the exclusion of a potentially
explosive atmosphere
7 Components on which intrinsic safety depends
7.1 Rating of components
7.2 Connectors for internal connections, plug-in cards,
and components
7.3 Fuses
7.4 Primary and secondary cells and batteries
7.5 Semiconductors
7.6 Failure of components and connections
7.7 Piezo-electric devices
8 Infallible components, infallible assemblies of
components and infallible connections
8.1 Mains transformers
8.2 Transformers other than mains transformers
8.3 Damping windings
8.4 Current limiting resistors
8.5 Blocking capacitors
8.6 Shunt safety assemblies
8.7 Wiring and connections
8.8 Galvanically separating components
9 Diode safety barriers
9.1 General
9.2 Construction
10 Type verifications and type tests
10.1 Spark-ignition test
10.2 Explosive test mixtures
10.3 Calibration of the spark-test apparatus
10.4 Tests with the spark-test apparatus
10.5 Temperature tests
10.6 Voltage tests
10.7 Small component ignition test
10.8 Determination of parameters of loosely specified
components
10.9 Tests for cells and batteries
10.10 Mechanical test
10.11 Tests for apparatus containing piezo-electric devices
10.12 Type tests for diode safety barriers and safety shunts
10.13 Cable pull test
10.14 Lamp Breakage Test
11 Routine verifications and tests
11.1 Routine tests for diode safety barriers
11.2 Routine test for mains transformers
12 Marking
12.1 General
12.2 Marking of connection facilities
12.3 Control drawings
13 Documentation
Annex A (normative) Assessment of intrinsically safe circuits
Annex B (normative) Spark-test apparatus for intrinsically
safe circuits
Annex C (informative) Measurement of creepage distances,
clearances, and separation distances
through casting compound and through
solid insulation
Annex D (normative) Encapsulation
Annex E (informative) U.S. National Deviations
Annex F (informative) Editorial Differences Between IEC 60079-11
and ANSI/ISA-12.02.01-2002 (IEC 60079-11 Mod)
Annex G (informative) National Differences Types
Gives the construction and testing of intrinsically safe apparatus, intended for use in potentially explosive atmospheres and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres.
Committee |
SP12.2
|
DevelopmentNote |
Formerly it was IAS-S12.02.01 (05/2001) Also numbered as UL 60079-11. (09/2003) Renumbered as ISA 60079-11 (09/2005)
|
DocumentType |
Standard
|
PublisherName |
International Society of Automation
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
ISA 12.13.01 : 2003 | PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS |
ISA 12.00.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
ISA 12.22.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS TYPE OF PROTECTION - FLAMEPROOF "D" |
ISA 12.23.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - ENCAPSULATION "M" |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
ISA 12.16.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY |
IEC 60127-3:2015 | Miniature fuses - Part 3: Sub-miniature fuse-links |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
ISA 12.00.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.