ISA 75.13 : 1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

METHOD OF EVALUATING THE PERFORMANCE OF POSITIONERS WITH ANALOG INPUT SIGNALS AND PNEUMATIC OUTPUT

Available format(s)

Hardcopy

Superseded date

03-12-2013

Superseded by

ISA 75.13.01 : 1996

Language(s)

English

Published date

01-01-1996

1 Scope
2 Purpose
3 Definitions
4 Testing procedures
     4.1 Introduction
     4.2 Test unit
     4.3 Environmental test conditions
     4.4 Supply conditions
5 Static behaviour
     5.1 Measurement (calibration) cycle
     5.2 Calibration curve
     5.3 Effect of influence quantities
     5.4 Flow capacity - supply and exhaust
     5.5 Flow gain (KQ)
     5.6 Steady-state consumption
     5.7 Locked-stem pressure gain (Kp)
     5.8 Accelerated life-cycle test
6 Dynamic response
     6.1 Introduction
     6.2 Test system
     6.3 Influence of test conditions
     6.4 Test equipment
     6.5 Test procedures
7 Presentation of test results
     7.1 Supporting information
     7.2 Static behaviour test results
     7.3 Dynamic behaviour test results
Figures
1 - Calibration curve (of data from Table 1)
2 - Supply pressure influence
3 - Ambient temperature influence
4 - Relative stem motion for typical linear actuator
5 - Test arrangement for electromagnetic susceptibility
6 - Test circuit for normal mode interference influence
7 - Test circuit for common mode interference influence
8 - Typical schematic for flow capacity tests
9 - Flow characteristic curve
10 - Locked-stem pressure gain (single-acting)
11 - Locked-stem pressure gain (double-acting)
12 - Schematic of simple dynamic response test system
13 - Steady-state characteristic of element exhibiting
     dead band and effect on output
14 - Steady-state characteristic of element exhibiting
     saturation and effect on output
15 - Recommended test signals
16 - Period variation
17 - Determination of phase shift for distorted output
Tables
1 - Calibration report
2 - Vibration levels used in the absence of manufacturer's
    specifications

Defines tests aimed at determining the performance of positioners with analog input signals and pneumatic output. The evaluation method outlined defines use of an actuator of the user's or manufacturer's choice. Positioners can be single- or double- acting.

Committee
SP75
DevelopmentNote
Formerly it was ISA-S75.13 (05/2001) Reaffirmed in 2007 & redesignated ISA 75.13 as ISA 75.13.01. (09/2007)
DocumentType
Standard
Pages
46
PublisherName
International Society of Automation
Status
Superseded
SupersededBy

ISA TR75.25.02 : 2000 CONTROL VALVE RESPONSE MEASUREMENT FROM STEP INPUTS
04/30110315 DC : DRAFT MAR 2004 IEC 60534-9 - INDUSTRIAL PROCESS CONTROL VALVES - PART 9: TEST PROCEDURE FOR RESPONSE MEASUREMENTS FROM STEP INPUTS
ISA 75.25.01 : 2000 TEST PROCEDURE FOR CONTROL VALVE RESPONSE MEASUREMENT FROM STEP INPUTS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.