ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components.
ISO 10848-4:2017 specifies laboratory and field measurements of buildings where at least one of the elements that form the construction under test is a Type A element (defined in ISO 10848‑1).
Laboratory measurements are used to quantify the performance of the junction with suppressed flanking transmission from the laboratory structure. Field measurements are used to characterize the in situ performance and it is not usually possible to suppress unwanted flanking transmission sufficiently; hence, the results are primarily representative of the performance of that junction when installed in that particular building structure.
The measured quantities can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.
Committee |
ISO/TC 43/SC 2
|
DevelopmentNote |
Supersedes ISO/DIS 10848-4. (09/2017)
|
DocumentType |
Standard
|
Pages |
7
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN ISO 10848-4:2010-12 | Identical |
BS EN ISO 10848-4:2010 | Identical |
DIN EN ISO 10848-4:2016-10 (Draft) | Identical |
UNI EN ISO 10848-4 : 2010 | Identical |
I.S. EN ISO 10848-4:2010 | Identical |
EN ISO 10848-4:2017 | Identical |
DIN EN ISO 10848-4:2018-02 | Identical |
BS EN ISO 10848-4:2017 | Identical |
ONORM EN ISO 10848-4 : 2018 | Identical |
NS EN ISO 10848-4 : 2017 | Identical |
NEN EN ISO 10848-4 : 2017 | Identical |
NBN EN ISO 10848-4 : 2010 | Identical |
PN EN ISO 10848-4 : 2017 | Identical |
UNE-EN ISO 10848-4:2018 | Identical |
UNE-EN ISO 10848-4:2011 | Identical |
I.S. EN ISO 10848-4:2017 | Identical |
NF EN ISO 10848-4 : 2017 | Identical |
GOST R ISO 10848-4 : 2013 | Identical |
SN EN ISO 10848-4 : 2010 | Identical |
I.S. EN ISO 12354-2:2017 | BUILDING ACOUSTICS - ESTIMATION OF ACOUSTIC PERFORMANCE OF BUILDINGS FROM THE PERFORMANCE OF ELEMENTS - PART 2: IMPACT SOUND INSULATION BETWEEN ROOMS (ISO 12354-2:2017) |
EN ISO 12354-2:2017 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 2: Impact sound insulation between rooms (ISO 12354-2:2017) |
BS EN ISO 12354-2:2017 | Building acoustics. Estimation of acoustic performance of buildings from the performance of elements Impact sound insulation between rooms |
EN ISO 12354-1:2017 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms (ISO 12354-1:2017) |
VDI 3762:2012-01 | Sound insulation by means of raised access floors and hollow floors |
DIN EN ISO 12354-1:2016-03 (Draft) | BUILDING ACOUSTICS - ESTIMATION OF ACOUSTIC PERFORMANCE OF BUILDINGS FROM THE PERFORMANCE OF ELEMENTS - PART 1: AIRBORNE SOUND INSULATION BETWEEN ROOMS (ISO 12354-1:2017) |
I.S. EN ISO 12354-1:2017 | BUILDING ACOUSTICS - ESTIMATION OF ACOUSTIC PERFORMANCE OF BUILDINGS FROM THE PERFORMANCE OF ELEMENTS - PART 1: AIRBORNE SOUND INSULATION BETWEEN ROOMS (ISO 12354-1:2017) |
EN ISO 10848-1:2017 | Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1: Frame document (ISO 10848-1:2017) |
ISO 12354-1:2017 | Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 1: Airborne sound insulation between rooms |
ISO 10848-1:2017 | Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms — Part 1: Frame document |
ISO 12354-2:2017 | Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 2: Impact sound insulation between rooms |
BS EN ISO 10848-1:2017 | Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms Frame document |
BS EN ISO 12354-1:2017 | Building acoustics. Estimation of acoustic performance of buildings from the performance of elements Airborne sound insulation between rooms |
I.S. EN ISO 10848-1:2017 | ACOUSTICS - LABORATORY AND FIELD MEASUREMENT OF FLANKING TRANSMISSION FOR AIRBORNE, IMPACT AND BUILDING SERVICE EQUIPMENT SOUND BETWEEN ADJOINING ROOMS - PART 1: FRAME DOCUMENT (ISO 10848-1:2017) |
ISO 10848-1:2017 | Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms — Part 1: Frame document |
ISO 10140-2:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 2: Measurement of airborne sound insulation |
ISO 12354-1:2017 | Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 1: Airborne sound insulation between rooms |
ISO 10140-3:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 3: Measurement of impact sound insulation |
ISO 12354-2:2017 | Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 2: Impact sound insulation between rooms |
ISO 12999-1:2014 | Acoustics Determination and application of measurement uncertainties in building acoustics Part 1: Sound insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.