ISO 12108:2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Metallic materials Fatigue testing Fatigue crack growth method
PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
28-09-2018
English, French
27-11-2002
ISO 12108 is intended to provide specifications for generation of fatigue crack growth rate data. Test results are expressed in terms of the fatigue crack growth rate as a function of crack-tip stress intensity factor range as defined by the theory of linear elastic fracture mechanics.
This International Standard describes a method of subjecting a precracked notched specimen to a cyclic force. The crack length is measured as a function of the number of elapsed force cycles. From the collected crack length and corresponding force cycles relationship the fatigue crack growth rate is determined and is expressed as a function of stress intensity factor range.
ISO 12018 describes tests for determining the fatigue crack growth rate from the threshold stress-intensity factor range to the onset of unstable crack extension as the maximum stress intensity factor approaches controlled instability. It is primarily intended for use in evaluating isotropic metallic materials under predominantly linear-elastic stress conditions and with force applied only perpendicular to the crack plane (mode I stress condition), and with a constant stress ratio.
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.