    Abstract - (Show below) - (Hide below)

    This International Standard specifies a method to determine if paints, varnishes, paint binders, solvents, petroleum or related products, when maintained at a selected equilibrium temperature and under the conditions of the test, give off sufficient flammable vapour to cause ignition on application of an external source of flame applied in a standard manner.

    This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3680.

    The method is suitable for use over the temperature range -30 °C to 110 °C, depending on the use of different apparatus listed in Table 1.

    The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons, should be considered with caution, as these mixtures can give anomalous results.

    General Product Information - (Show below) - (Hide below)

    Committee ISO/TC 28
    Development Note Supersedes ISO/FDIS 1516 (04/2002)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS ISO 4433-1:1997 Thermoplastic pipes. Resistance to liquid chemicals. Classification Immersion test method
    03/300855 DC : DRAFT JAN 2003 ISO 3680 - DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD
    I.S. EN 15060:2006 PAINTS AND VARNISHES - GUIDE FOR THE CLASSIFICATION AND SELECTION OF COATING SYSTEMS FOR WOOD BASED MATERIALS IN FURNITURE FOR INTERIOR USE
    CEN/TR 15138:2005 Petroleum products and other liquids - Guide to flash point testing
    I.S. EN 1860-3:2003 APPLIANCES, SOLID FUELS AND FIRELIGHTERS FOR BARBECUEING - PART 3: FIRELIGHTERS FOR IGNITING SOLID FUELS FOR USE IN BARBECUE APPLIANCES - REQUIREMENTS AND TEST METHODS
    BS 2000-524(2004) : 2004 METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - BS 2000-524: DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD
    BS 7952:2001 Specification for chemical firelighters in solid form used for the ignition of solid fuels in residential heating and cooking appliances
    ISO/TR 29662:2009 Petroleum products and other liquids Guidance for flash point testing
    I.S. EN ISO 3679:2015 DETERMINATION OF FLASH NO-FLASH AND FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD (ISO 3679:2015)
    BS 3900-A13:1986 Methods of test for paints Test for flash/no flash (rapid equilibrium method)
    BS 3900-A9:1986 Methods of test for paints Determination of flashpoint (closed cup equilibrium method)
    I.S. EN ISO 3680:2004 DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD
    API 3000 : 2014 CLASSIFYING AND LOADING OF CRUDE OIL INTO RAIL TANK CARS
    BS 2782-11.1161A(1998) : 1998 METHODS OF TESTING PLASTICS - THERMOPLASTICS PIPES, FITTINGS AND VALVES - THERMOPLASTICS PIPES - RESISTANCE TO LIQUID CHEMICALS - CLASSIFICATION - IMMERSION TEST METHOD
    BS 2000-523(2015) : 2015 DETERMINATION OF FLASH NO-FLASH AND FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD
    BS 135; 458; 805:1977 Specifications for benzene, xylenes and toluenes
    PD ISO/TR 11018:2001 Essential oils. General guidance on the determination of flashpoint
    DIN EN ISO 3679:2015-06 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
    ISO 1523:2002 Determination of flash point — Closed cup equilibrium method
    BS EN ISO 3680:2004 Methods of test for petroleum and its products. BS 2000-524. Determination of flash/no flash. Rapid equilibrium closed cup method
    DIN 55680:1983-08 PAINTS, VARNISHES AND RELATED PRODUCTS; FLASH/NO FLASH TEST; RAPID EQUILIBRIUM METHOD; ISO 3680 MODIFIED
    BS EN 15060:2006 Paints and varnishes. Guide for the classification and selection of coating systems for wood based materials in furniture for interior use
    13/30285144 DC : 0 BS ISO 3679 - DETERMINATION OF FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD
    I.S. CEN/TR 15138:2005 PETROLEUM PRODUCTS AND OTHER LIQUIDS - GUIDE TO FLASH POINT TESTING
    ISO/TR 11018:1997 Essential oils General guidance on the determination of flashpoint
    ISO 3679:2015 Determination of flash no-flash and flash point — Rapid equilibrium closed cup method
    BS EN ISO 3679:2015 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
    UNE-EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
    ISO 3680:2004 Determination of flash/no flash Rapid equilibrium closed cup method
    EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
    EN 15060:2006 Paints and varnishes - Guide for the classification and selection of coating systems for wood based materials in furniture for interior use
    EN 1860-3:2003/A1:2006 APPLIANCES, SOLID FUELS AND FIRELIGHTERS FOR BARBECUEING - PART 3: FIRELIGHTERS FOR IGNITING SOLID FUELS FOR USE IN BARBECUE APPLIANCES - REQUIREMENTS AND TEST METHODS
    EN ISO 3680:2004 Determination of flash/no flash - Rapid equilibrium closed cup method (ISO 3680:2004)
    EN ISO 1523:2002 Determination of flash point - Closed cup equilibrium method (ISO 1523:2002)
    PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
    PD CEN/TR 15138:2005 Petroleum products and other liquids. Guide to flash point testing
    BS EN ISO 1523:2002 Method of test for petroleum and its products. Determination of flash point. Closed cup equilibrium method
    BS EN 1860-3:2003 Appliances, solid fuels and firelighters for barbecueing Firelighters for igniting solid fuels for use in barbecue appliances. Requirements and test methods
    DIN EN ISO 3680:2004-07 DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 3171:1988 Petroleum liquids — Automatic pipeline sampling
    ISO 2719:2016 Determination of flash point — Pensky-Martens closed cup method
    ISO 3170:2004 Petroleum liquids — Manual sampling
    ISO 3679:2015 Determination of flash no-flash and flash point — Rapid equilibrium closed cup method
    ISO 15528:2013 Paints, varnishes and raw materials for paints and varnishes Sampling
    ISO 1523:2002 Determination of flash point — Closed cup equilibrium method
    ISO 1513:2010 Paints and varnishes Examination and preparation of test samples
    ISO 3680:2004 Determination of flash/no flash Rapid equilibrium closed cup method
    ISO 13736:2013 Determination of flash point Abel closed-cup method
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective