• ISO 16283-2:2015

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Acoustics — Field measurement of sound insulation in buildings and of building elements — Part 2: Impact sound insulation

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  13-07-2020

    Language(s):  French, English

    Published date:  13-11-2015

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 16283-2:20015 specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field might, or might not approximate to a diffuse field.

    Two impact sources are described: the tapping machine and the rubber ball. These impact sources do not exactly replicate all possible types of real impacts on floors or stairs in buildings.

    The tapping machine can be used to assess a variety of light, hard impacts such as footsteps from walkers wearing hard-heeled footwear or dropped objects. A single number quantity can be calculated using the rating procedures in ISO 717‑2. This single number quantity links the measured impact sound insulation using the tapping machine to subjective assessment of general impacts in dwellings that occur on floors or stairs in a building. The tapping machine is also well-suited to the prediction of impact sound insulation using ISO 15712‑2. These two aspects facilitate the specification of impact sound insulation in national building requirements using only measurements with the tapping machine as an impact source.

    The rubber ball can be used to assess heavy, soft impacts such as from walkers in bare feet or children jumping, as well as quantifying absolute values that can be related to human disturbance in terms of a Fast time-weighted maximum sound pressure level. At present, calculation procedures for a single number quantity do not currently exist in an ISO Standard.

    General Product Information - (Show below) - (Hide below)

    Committee ISO/TC 43/SC 2
    Development Note Supersedes ISO 140-14 and ISO 140-7. (11/2015) Supersedes ISO/DIS 16283-2. (05/2018)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN ISO 12354-2:2017 BUILDING ACOUSTICS - ESTIMATION OF ACOUSTIC PERFORMANCE OF BUILDINGS FROM THE PERFORMANCE OF ELEMENTS - PART 2: IMPACT SOUND INSULATION BETWEEN ROOMS (ISO 12354-2:2017)
    EN ISO 12354-2:2017 Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 2: Impact sound insulation between rooms (ISO 12354-2:2017)
    BS EN ISO 12354-2:2017 Building acoustics. Estimation of acoustic performance of buildings from the performance of elements Impact sound insulation between rooms
    17/30342985 DC : 0 BS ISO 19488 - ACOUSTICS - ACOUSTIC CLASSIFICATION OF DWELLINGS
    ISO 12354-2:2017 Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 2: Impact sound insulation between rooms

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61672-2:2013+AMD1:2017 CSV Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
    ISO 717-2:2013 Acoustics Rating of sound insulation in buildings and of building elements Part 2: Impact sound insulation
    ISO 3382-2:2008 Acoustics Measurement of room acoustic parameters Part 2: Reverberation time in ordinary rooms
    IEC 60942:2003 Electroacoustics - Sound calibrators
    OIML R 58 : 1998 SOUND LEVEL METERS
    ISO 10052:2004 Acoustics Field measurements of airborne and impact sound insulation and of service equipment sound Survey method
    OIML R 88 : 1998 INTEGRATING-AVERAGING SOUND LEVEL METERS
    ISO 18233:2006 Acoustics Application of new measurement methods in building and room acoustics
    ISO 10140-3:2010 Acoustics Laboratory measurement of sound insulation of building elements Part 3: Measurement of impact sound insulation
    ISO 10140-5:2010 Acoustics Laboratory measurement of sound insulation of building elements Part 5: Requirements for test facilities and equipment
    IEC 61672-3:2013 Electroacoustics - Sound level meters - Part 3: Periodic tests
    ISO 12354-2:2017 Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 2: Impact sound insulation between rooms
    ISO 12999-1:2014 Acoustics Determination and application of measurement uncertainties in building acoustics Part 1: Sound insulation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications