ISO 16345:2014 covers the measurement of the thermal performance and pumping head of open- and closed-circuit, mechanical draft, wet and wet/dry cooling towers and natural draft and fan-assisted natural draft, wet and wet/dry cooling towers. The standard rating boundaries for series mechanical draft, open- and closed-circuit cooling towers are specified.
ISO 16345:2014 does not apply to the testing and rating of closed-circuit towers where the process fluid undergoes a change in phase as it passes through the heat exchanger or where the thermophysical properties of the process fluid are not available.
Committee |
ISO/TC 86/SC 6
|
DevelopmentNote |
Supersedes ISO/DIS 16345. (05/2014)
|
DocumentType |
Standard
|
Pages |
151
|
ProductNote |
THIS STANDARD ALSO REFERS TO ISO 9551,ISO 10790:1990/Corr.1:2003
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
Standards | Relationship |
NEN ISO 16345 : 2014 | Identical |
BS ISO 16345:2014 | Identical |
ISO/TR 15377:2007 | Measurement of fluid flow by means of pressure-differential devices Guidelines for the specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167 |
ISO/TR 12767:2007 | Measurement of fluid flow by means of pressure differential devices — Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167 |
ISO 5167-3:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles |
ISO 7066-2:1988 | Assessment of uncertainty in the calibration and use of flow measurement devices — Part 2: Non-linear calibration relationships |
ISO 2975-3:1976 | Measurement of water flow in closed conduits — Tracer methods — Part 3: Constant rate injection method using radioactive tracers |
ISO 13359:1998 | Measurement of conductive liquid flow in closed conduits Flanged electromagnetic flowmeters Overall length |
ISO 2975-7:1977 | Measurement of water flow in closed conduits — Tracer methods — Part 7: Transit time method using radioactive tracers |
ISO 14511:2001 | Measurement of fluid flow in closed conduits Thermal mass flowmeters |
ISO 9300:2005 | Measurement of gas flow by means of critical flow Venturi nozzles |
ISO 2975-1:1974 | Measurement of water flow in closed conduits — Tracer methods — Part 1: General |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
ASHRAE 41.6 : 2014 | METHOD FOR HUMIDITY MEASUREMENT |
ISO 9368-1:1990 | Measurement of liquid flow in closed conduits by the weighing method — Procedures for checking installations — Part 1: Static weighing systems |
ISO 2975-6:1977 | Measurement of water flow in closed conduits — Tracer methods — Part 6: Transit time method using non-radioactive tracers |
ISO 4677-1:1985 | Atmospheres for conditioning and testing Determination of relative humidity Part 1: Aspirated psychrometer method |
ISO/TR 5168:1998 | Measurement of fluid flow Evaluation of uncertainties |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
ISO 8316:1987 | Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank |
ISO/TR 3313:1998 | Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments |
ISO 6817:1992 | Measurement of conductive liquid flow in closed conduits Method using electromagnetic flowmeters |
ISO/TR 9464:2008 | Guidelines for the use of ISO 5167:2003 |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 14164:1999 | Stationary source emissions — Determination of the volume flowrate of gas streams in ducts — Automated method |
ASTM E 337 : 2015 : REDLINE | Standard Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures) |
ISO 10790:2015 | Measurement of fluid flow in closed conduits Guidance to the selection, installation and use of Coriolis flowmeters (mass flow, density and volume flow measurements) |
ISO/TR 12764:1997 | Measurement of fluid flow in closed conduits Flowrate measurement by means of vortex shedding flowmeters inserted in circular cross-section conduits running full |
ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
ISO 11631:1998 | Measurement of fluid flow Methods of specifying flowmeter performance |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
ISO 2975-2:1975 | Measurement of water flow in closed conduits — Tracer methods — Part 2: Constant rate injection method using non-radioactive tracers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.