ISO 16645:2016
Current
The latest, up-to-date edition.
Radiological protection — Medical electron accelerators — Requirements and recommendations for shielding design and evaluation
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
19-09-2016
ISO 16645:2016 is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.
The cyclotrons and the synchrotrons used for hadrontherapy are not considered.
The radiation protection requirements and recommendations given in ISO 16645:2016 cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).
DevelopmentNote |
Supersedes ISO/DIS 16645. (09/2016)
|
DocumentType |
Standard
|
Pages |
76
|
ProductNote |
THIS STANDARD ALSO HAVE A CORRECTED VERSION EN 2016-11
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
PN-EN ISO 16645:2019-07 | Identical |
I.S. EN ISO 16645:2019 | Identical |
EN ISO 16645:2019 | Identical |
NS-EN ISO 16645 : 2019 | Identical |
NEN-EN-ISO 16645:2019 en | Identical |
UNI EN ISO 16645:2019 | Identical |
NF ISO 16645 : 2017 | Identical |
UNE-EN ISO 16645:2019 | Identical |
NF EN ISO 16645:2019 | Identical |
DIN EN ISO 16645:2020-07 | Identical |
ÖNORM EN ISO 16645: 2019 12 15 | Identical |
BS EN ISO 16645:2019 | Identical |
SN EN ISO 16645:2020 | Identical |
ISO 14152:2001 | Neutron radiation protection shielding — Design principles and considerations for the choice of appropriate materials |
DIN 6847-2:2014-03 | Medical electron accelerators - Part 2: Rules for construction of structural radiation protection |
IEC 60976:2007 | Medical electrical equipment - Medical electron accelerators - Functional performance characteristics |
IEC 60601-2-1:2009+AMD1:2014 CSV | Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV |
ISO 12749-2:2013 | Nuclear energy, nuclear technologies, and radiological protection — Vocabulary — Part 2: Radiological protection |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.