ISO 17664:2004

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Sterilization of medical devices Information to be provided by the manufacturer for the processing of resterilizable medical devices

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

04-09-2018

Superseded by

ISO 17664:2017

Language(s)

English

Published date

25-02-2004

€60.00
Excluding VAT

ISO 17664:2004 specifies the information to be provided by the medical device manufacturer on the processing of medical devices claimed to be resterilizable, and medical devices intended to be sterilized by the processor. ISO 17664:2004 specifies requirements for the information to be provided by the medical device manufacturer, so that the medical device can be processed safely and will continue to meet its performance specification.

Requirements are specified for processing that consists of all or some of the following activities:

a) preparation at the point of use;

b) preparation, cleaning, disinfection;

c) drying;

d) inspection, maintenance and testing;

e) packaging;

f) sterilization;

g) storage.

When providing instructions for these activities, medical device manufacturers are expected to be aware of the training and knowledge of procedures, and of the processing equipment available to the persons likely to be responsible for processing. It is likely that some processing procedures will be generic and well known and will use equipment and consumables conforming to recognized standards. In this case, a reference in the instructions is all that is required. For those medical devices where instructions for use are not required to accompany the medical device, other means of communicating the information can be used, e.g. user manuals, symbols or wall charts supplied separately.

The principles of ISO 17664:2004 may be applied when considering the information to be supplied with medical devices which only require disinfection prior to re-use.

ISO 17664:2004 is not applicable to textile devices used in patient-draping systems or surgical clothing.

DocumentType
Standard
Pages
18
PublisherName
International Organization for Standardization
Status
Withdrawn
SupersededBy

Standards Relationship
EN ISO 17664:2004 Identical
UNE-EN ISO 17664:2004 Identical
BS EN ISO 17664:2004 Identical