• ISO 2507-1:1995

    Current The latest, up-to-date edition.

    Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English, French

    Published date:  02-02-1995

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    The method specified is based on determining the temperature at which a standard indenter, under a force of 50 N ± 1 N, penetrates 1 mm into the surface of a test piece cut from the wall of a pipe or fitting while the temperature is raised at a constant rate. Is applicable only to thermoplastics materials for which it is possible to measure the temperature at which the rate of softening becomes rapid. Is based on ISO 306:1994 which, however, applies to materials in the form of sheets.

    General Product Information - (Show below) - (Hide below)

    Committee ISO/TC 138/SC 5
    Development Note Supersedes ISO 2507 (04/2001)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC U) Pipes
    12/30255878 DC : 0 BS ISO 17885 - PLASTICS PIPING SYSTEMS - MECHANICAL FITTINGS FOR PRESSURE PIPING SYSTEMS - SPECIFICATIONS
    17/30339710 DC : 0 BS ISO 21138-3 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: PIPES AND FITTINGS WITH NON-SMOOTH EXTERNAL SURFACE, TYPE B
    17/30339707 DC : 0 BS ISO 21138-2 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: PIPES AND FITTINGS WITH SMOOTH EXTERNAL SURFACE, TYPE A
    14/30310352 DC : 0 BS EN 12200-1 - PLASTICS RAINWATER PIPING SYSTEMS FOR ABOVE GROUND EXTERNAL USE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    BS ISO 10931-1:1997 Plastics piping systems for industrial applications. Poly (vinylidene fluoride) General
    UNI EN ISO 11296-3 : 2011 PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES
    14/30311109 DC : 0 BS EN 1453-1 - PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    NF EN ISO 11296-3 : 2011 PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES
    13/30280432 DC : 0 BS ISO 16422 - PIPES AND JOINTS MADE OF ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) FOR THE CONVEYANCE OF WATER UNDER PRESSURE - SPECIFICATIONS
    DIN EN ISO 11296-3:2011-07 PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES
    06/30136260 DC : DRAFT MAR 2006 ISO 21138-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYLCHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 1 - MATERIAL AND PERFORMANCE SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS
    PREN 1401-1 : DRAFT 2018 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS
    17/30363921 DC : 0 BS EN 17176-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
    EN ISO 11296-3:2011 Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)
    I.S. EN ISO 9080:2012 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION (ISO 9080:2012)
    ONORM EN 1329-1 : 2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    BS ISO 16149:2006 Agricultural irrigation equipment. PVC above-ground low-pressure pipe for surface irrigation. Specifications and test methods
    08/30168684 DC : DRAFT JULY 2008 BS EN ISO 1452-3 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY (VINYL CHLORIDE) (PVC U) - PART 3: FITTINGS
    UNE-EN ISO 1452-3:2011 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings (ISO 1452-3:2009, corrected version 2010-03-01)
    16/30314617 DC : 0 BS ISO 19469-3 - PLASTIC PIPING SYSTEMS FOR NON PRESSURE UNDERGROUND DRAINAGE - SINGLE WALL CORRUGATED PIPING SYSTEMS OF POLYETHYLENE (PE), POLYPROPYLENE (PP) AND UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: PIPES AND FITTINGS FOR DEEP BURIAL INSTALLATIONS
    03/115115 DC : DRAFT OCT 2003 ISO 16422 - PIPES AND JOINTS MADE OF ORIENTED UNPLASTICIZED POLY (VINYL CHLORIDE) (PVC-O) FOR THE CONVEYANCE OF WATER - SPECIFICATIONS
    PREN 17176-3 : DRAFT 2017 PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 3: FITTINGS
    08/30168675 DC : DRAFT JULY 2008 BS EN ISO 1452-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC U) - PART 2: PIPES
    PREN 1329-1 : DRAFT 2013 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    I.S. EN ISO 1452-3:2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS
    04/30081969 DC : DRAFT AUG 2004 ISO 6993-1 - BURIED, HIGH-IMPACT POLY (VINYL CHLORIDE) (PVC-HI) PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - PART 1: PIPES OPERATING PRESSURE OF 1 BAR (100 KPA)
    PREN 13476-2 : DRAFT 2015 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
    UNI EN 1329-1 : 2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    I.S. EN 13476-3:2007 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY (VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
    ISO 4422-3:1996 Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply Specifications Part 3: Fittings and joints
    I.S. EN ISO 11296-3:2011 PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES
    BS EN ISO 11296-3:2011 Plastics piping systems for renovation of under ground non-pressure drainage and sewerage networks Lining with close-fit pipes
    18/30371677 DC : DRAFT MAY 2018 BS EN 1401-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS
    BS EN 1329-1 : 2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    ISO 17885:2015 Plastics piping systems Mechanical fittings for pressure piping systems Specifications
    UNE-EN ISO 9080:2013 Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation (ISO 9080:2012)
    ISO/TR 9080:1992 Thermoplastics pipes for the transport of fluids — Methods of extrapolation of hydrostatic stress rupture data to determine the long-term hydrostatic strength of thermoplastics pipe materials
    DIN EN 1453-1:2017-09 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    I.S. EN 1453-1:2017 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1 - SPECIFICATIONS FOR PIPES AND THE SYSTEM
    NF EN ISO 1452-2 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
    PREN 12200-1 : DRAFT 2014 PLASTICS RAINWATER PIPING SYSTEMS FOR ABOVE GROUND EXTERNAL USE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    NF EN ISO 1452-4 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES
    UNI EN ISO 1452-4 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES
    BS ISO 17885:2015 Plastics piping systems. Mechanical fittings for pressure piping systems. Specifications
    DIN EN ISO 1452-2:2010-04 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
    12/30265313 DC : 0 BS EN 124-6 - GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 6: GULLY TOPS AND MANHOLE TOPS MADE FROM POLYPROPYLENE (PP) OR POLYVINYL-CHLORIDE (PVC-U)
    PREN 1453-1 : DRAFT 2014 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    PREN 17176-2 : DRAFT 2017 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
    DIN EN ISO 1452-4:2010-04 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4: Valves (ISO 1452-4:2009)
    DIN EN ISO 1452-3:2010-04 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings (ISO 1452-3:2009)
    ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 2: Pipes
    EN 13476-3:2018 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
    ISO 21138-3:2007 Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 3: Pipes and fittings with non-smooth external surface, Type B
    I.S. EN 1329-1:2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    I.S. EN ISO 1452-2:2009 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
    UNE-EN ISO 11296-3:2011 Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)
    PREN 13476-3 : DRAFT 2015 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
    ISO 6993-3:2006 Buried, high-impact poly(vinyl chloride) (PVC-HI) piping systems for the supply of gaseous fuels Part 3: Fittings and saddles for a maximum operating pressure of 1 bar (100 kPa)
    ISO 11296-3:2009 Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks Part 3: Lining with close-fit pipes
    DIN EN ISO 9080 E : 2003 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION
    DIN EN 1453-1:2000-03 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    UNE-EN 1453-1:2017 Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system
    EN 13476-2:2018+A1:2020 Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A
    UNI EN ISO 9080 : 2012 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION
    13/30280703 DC : 0 BS EN 1329-1 - PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
    BS EN ISO 1452-4:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC U) Valves
    11/30211183 DC : 0 BS ISO 16422 - PIPES AND JOINTS MADE OF ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) FOR THE CONVEYANCE OF WATER UNDER PRESSURE - SPECIFICATIONS
    08/30174001 DC : DRAFT JUNE 2008 BS ISO 11296-3 - PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES
    BS ISO 15398:2012 Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas
    ISO 21138-2:2007 Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 2: Pipes and fittings with smooth external surface, Type A
    BS EN ISO 2507-2:2017 Thermoplastics pipes and fittings. Vicat softening temperature Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
    ISO 16149:2006 Agricultural irrigation equipment PVC above-ground low-pressure pipe for surface irrigation Specifications and test methods
    ISO 6993-2:2006 Buried, high-impact poly(vinyl chloride) (PVC-HI) piping systems for the supply of gaseous fuels Part 2: Fittings for a maximum operating pressure of 200 mbar (20 kPa)
    UNE-EN ISO 2507-3:2018 Thermoplastics pipes and fittings - Vicat softening temperature - Part 3: Test conditions for acrylonitrile/butadiene/styrene (ABS) and acrylonitrile/styrene/acrylic ester (ASA) pipes and fittings (ISO 2507-3:1995)
    ISO 21138-1:2007 Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 1: Material specifications and performance criteria for pipes, fittings and system
    ISO 6993:2001 Buried, high-impact poly(vinyl chloride) (PVC-HI) pipes for the supply of gaseous fuels Specifications
    ISO 1452-4:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 4: Valves
    BS EN 1453-1:2000 Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings. Unplasticized poly (vinyl chloride) (PVC-U) Specifications for pipes and the system
    BS EN ISO 9080:2012 Plastics piping and ducting systems. Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
    EN 1453-1:2017/AC:2017 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    ISO 15493:2003 Plastics piping systems for industrial applications Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) Specifications for components and the system Metric series
    ISO 9080:2012 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
    ISO 10931:2005 Plastics piping systems for industrial applications Poly(vinylidene fluoride) (PVDF) Specifications for components and the system
    EN ISO 10931:2005/A1:2015 Plastics piping systems for industrial applications - Poly(vinylidene fluoride) (PVDF) - Specifications for components and the system (ISO 10931:2005/FDAM 1:2015)
    EN ISO 15493:2003/A1:2017 Plastics piping systems for industrial applications - Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) - Specifications for components and the system - Metric series - Amendment 1 (ISO 15493:2003/Amd 1:2016 + Cor 1:2004)
    EN ISO 1452-4:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4: Valves (ISO 1452-4:2009)
    EN ISO 1452-3:2010 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings (ISO 1452-3:2009, corrected version 2010-03-01)
    EN ISO 9080:2012 Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation (ISO 9080:2012)
    EN ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
    11/30245512 DC : 0 BS ISO 15398 - SPECIFICATIONS FOR THERMOPLASTICS COVERS AND FRAMES FOR MANHOLES AND INSPECTION CHAMBERS USED IN NON-TRAFFIC AREAS
    06/30136263 DC : DRAFT MAR 2006 ISO 21138-2 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYLCHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2 - PIPES AND FITTINGS WITH SMOOTH EXTERNAL SURFACE - TYPE A
    10/30228627 DC : 0 BS EN ISO 1452-3 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS
    UNI EN ISO 1452-3 : 2010-12 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS
    16/30314675 DC : 0 BS ISO 19469-1 - PLASTIC PIPING SYSTEMS FOR NON PRESSURE UNDERGROUND DRAINAGE - SINGLE WALL CORRUGATED PIPING SYSTEMS OF POLYETHYLENE (PE), POLYPROPYLENE (PP) AND UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL REQUIREMENTS AND PERFORMANCE CHARACTERISTICS
    I.S. EN ISO 2507-3:2017 THERMOPLASTICS PIPES AND FITTINGS - VICAT SOFTENING TEMPERATURE - PART 3: TEST CONDITIONS FOR ACRYLONITRILE/BUTADIENE/STYRENE (ABS) AND CRYLONITRILE/STYRENE/ACRYLIC ESTER (ASA) PIPES AND FITTINGS (ISO 2507-3:1995)
    NF EN ISO 1452-3 : DEC 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS
    BS ISO 16422:2014 Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure. Specifications
    BS EN ISO 1452-3:2010 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC-U) Fittings
    UNI EN ISO 1452-2 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
    15/30327636 DC : 0 BS EN 13476-3 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
    I.S. EN ISO 2507-2:2017 THERMOPLASTICS PIPES AND FITTINGS - VICAT SOFTENING TEMPERATURE - PART 2: TEST CONDITIONS FOR UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) OR CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) PIPES AND FITTINGS AND FOR HIGH IMPACT RESISTANCE POLY (VINYL CHLORIDE) (PVC-HI) PIPES (ISO 2507-2:1995)
    15/30327639 DC : 0 BS EN 13476-2 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
    ISO 16422:2014 Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Specifications
    ISO 1452-3:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 3: Fittings
    ISO 6993-1:2006 Buried, high-impact poly(vinyl chloride) (PVC-HI) piping systems for the supply of gaseous fuels Part 1: Pipes for a maximum operating pressure of 1 bar (100 kPa)
    UNE-ISO 16422:2015 Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure. Specifications
    UNE-EN ISO 2507-2:2018 Thermoplastics pipes and fittings - Vicat softening temperature - Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes (ISO 2507-2:1995)
    17/30363927 DC : 0 BS EN 17176-3 - PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 3: FITTINGS
    ISO 15398:2012 Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas
    I.S. EN 13476-2:2007 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY (VINYLCHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
    EN 13476-2:2018 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
    EN 1329-1:2014+A1:2018 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the systems
    I.S. EN ISO 1452-4:2009 LASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES
    DIN EN ISO 10931:2015-11 PLASTICS PIPING SYSTEMS FOR INDUSTRIAL APPLICATIONS - POLY(VINYLIDENE FLUORIDE) (PVDF) - SPECIFICATIONS FOR COMPONENTS AND THE SYSTEM (ISO 10931:2005 + AMD 1:2015)
    BS EN ISO 10931 : 2005 PLASTICS PIPING SYSTEMS FOR INDUSTRIAL APPLICATIONS - POLY(VINYLIDENE FLUORIDE) (PVDF) - SPECIFICATIONS FOR COMPONENTS AND THE SYSTEM
    BS EN ISO 15493 : 2003 PLASTICS PIPING SYSTEMS FOR INDUSTRIAL APPLICATIONS - ACRYLONITRILE-BUTADIENE-STYRENE (ABS), UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) AND CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - SPECIFICATIONS FOR COMPONENTS AND THE SYSTEM - METRIC SERIES (ISO 15493:2003)
    DIN EN ISO 9080:2003-10 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective