ISO 389-7:2005
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
07-11-2019
03-11-2005
ISO 389-7:2005 specifies a reference threshold of hearing for the calibration of audiometric equipment used under the following conditions.
- The sound field in the absence of the listener consists of either a free progressive plane wave (free field) or a diffuse sound field, as specified in ISO 8253-2. In the case of a free field, the source of sound is directly in front of the listener (frontal incidence).
- The sound signals are pure (sinusoidal) tones in the case of free-field conditions and one-third octave bands of (white or pink) noise in the case of diffuse-field conditions.
- The sound pressure level is measured in the absence of the listener at the position where the centre of the listener's head would be.
- Listening is binaural.
The data in ISO 389-7:2005 are given in numerical form for the preferred frequencies in the one-third octave series from 20 Hz to 16 000 Hz inclusive in accordance with ISO 266 and, in addition, for some intermediate audiometric frequencies up to 18 000 Hz.
The threshold data differ from the audiometric zero specified in ISO 389-1, ISO 389-2, ISO/TR 389-5 and ISO 389-8, since the latter refer to monaural listening through earphones with sound pressure levels referred to specified couplers and ear simulators. Direct comparison between the data in the parts of ISO 389 mentioned above and that in ISO 389-7:2005 is therefore not appropriate.
DevelopmentNote |
Supersedes ISO/DIS 389-7 (11/2005)
|
DocumentType |
Standard
|
Pages |
10
|
ProductNote |
THIS STANDARD ALSO REFERS TO CEI 60645-1,CEI 60645-4
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
DIN EN ISO 389-7:1998-12 | Identical |
ONORM EN ISO 389-7 : 2017 | Identical |
DIN EN ISO 389-7:2006-04 | Identical |
NF EN ISO 389-7 : 2006 AMD 1 2016 | Identical |
GOST R ISO 389-7 : 2011 | Identical |
NBN EN ISO 389-7 : 2006 AMD 1 2016 | Identical |
NEN EN ISO 389-7 : 2006 AMD 1 2016 | Identical |
NS EN ISO 389-7 : 1998 | Identical |
I.S. EN ISO 389-7:2005 | Identical |
PN-EN ISO 389-7:2009/A1:2016-10 | Identical |
SN EN ISO 389-7 : 2006 AMD 1 2016 | Identical |
UNI EN ISO 389-7 : 2006 | Identical |
EN ISO 389-7:2005 | Identical |
UNE-EN ISO 389-7:2006 | Identical |
BS EN ISO 389-7 : 2005 | Identical |
UNI EN ISO 389-7:2016 | Identical |
BS EN ISO 389-7:2005+A1:2016 | Identical |
BS EN ISO 389-9:2009 | Acoustics. Reference zero for the calibration of audiometric equipment Preferred test conditions for the determination of reference hearing threshold levels |
UNI ISO 1996-2 : 2010 | ACOUSTICS - DESCRIPTION, MEASUREMENT AND ASSESSMENT OF ENVIRONMENTAL NOISE - PART 2: DETERMINATION OF ENVIRONMENTAL NOISE LEVELS |
17/30359986 DC : 0 | BS EN ISO 7779 - ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT |
ISO 532-2:2017 | Acoustics — Methods for calculating loudness — Part 2: Moore-Glasberg method |
ANSI S3.4 : 2007 : R2012 | PROCEDURE FOR THE COMPUTATION OF LOUDNESS OF STEADY SOUNDS |
BS EN ISO 8253-1:2010 | Acoustics. Audiometric test methods Pure-tone air and bone conduction audiometry |
BS ISO 28961:2012 | Acoustics. Statistical distribution of hearing thresholds of otologically normal persons in the age range from 18 years to 25 years under free-field listening conditions |
14/30313972 DC : 0 | BS EN 60645-1 ED.4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
16/30275393 DC : 0 | BS ISO 532-2 - ACOUSTICS - METHODS FOR CALCULATING LOUDNESS - PART 2: MOORE-GLASBERG METHOD |
EN ISO 7779:2010 | Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment (ISO 7779:2010) |
UNI EN ISO 7779 : 2010 | ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT |
UNI EN ISO 389-9 : 2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
I.S. EN ISO 8253-2:2009 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 2: SOUND FILED AUDIOMETRY WITH PURE-TONE AND NARROW-BAND TEST SIGNALS |
DIN EN ISO 7779:2011-01 | ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT |
DIN ISO 226:2006-04 | ACOUSTICS - NORMAL EQUAL-LOUDNESS-LEVEL CONTOURS |
I.S. EN ISO 8253-1:2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
CEI EN 60645-1 : 2016 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY |
DIN EN ISO 389-9:2009-12 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
BS EN 60645-4:1995 | Audiometers Equipment for extended high-frequency audiometry |
ECMA 74 : 14ED 2017 | MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
UNI ISO 28961 : 2012 | ACOUSTICS - STATISTICAL DISTRIBUTION OF HEARING THRESHOLDS OF OTOLOGICALLY NORMAL PERSONS IN THE AGE RANGE FROM 18 YEARS TO 25 YEARS UNDER FREE-FIELD LISTENING CONDITIONS |
17/30333265 DC : 0 | BS EN ISO 389-1 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 1: REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES AND SUPRA-AURAL EARPHONES |
ANSI S3.6 : 2010 | SPECIFICATION FOR AUDIOMETERS |
10/30214511 DC : 0 | BS ISO 28961 - ACOUSTICS - STATISTICAL DISTRIBUTION OF NORMAL HEARING THRESHOLDS UNDER FREE-FIELD LISTENING CONDITIONS |
15/30328565 DC : 0 | BS EN 60645-1 ED4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
UNE-EN ISO 7779:2011 | Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment (ISO 7779:2010) |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
ISO 28961:2012 | Acoustics — Statistical distribution of hearing thresholds of otologically normal persons in the age range from 18 years to 25 years under free-field listening conditions |
BS EN ISO 7779:2010 | Acoustics. Measurement of airborne noise emitted by information technology and telecommunications equipment |
ISO 8253-2:2009 | Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals |
UNE-EN ISO 8253-2:2010 | Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test signals (ISO 8253-2:2009) |
IEC 60645-4:1994 | Audiometers - Part 4: Equipment for extended high-frequency audiometry |
UNE-EN ISO 8253-1:2011 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
BS EN ISO 8253-2:2009 | Acoustics. Audiometric test methods Sound field audiometry with pure-tone and narrow-band test signals |
ANSI/ASA S12.10 PART 1:2010(R2020) | ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT - PART 1: DETERMINATION OF SOUND POWER LEVEL AND EMISSION SOUND PRESSURE LEVEL |
EN ISO 8253-1:2010 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
UNI EN ISO 8253-2 : 2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 2: SOUND FIELD AUDIOMETRY WITH PURE-TONE AND NARROW-BAND TEST SIGNALS |
UNI EN ISO 8253-1 : 2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
11/30216799 DC : 0 | BS ISO 532-1 - ACOUSTICS - METHOD FOR CALCULATING LOUDNESS - PART 1: STATIONARY SOUNDS |
I.S. EN ISO 7779:2010 | ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT |
PD 6545:2005 | Intended use of human head and ear simulators-guide |
08/30176438 DC : DRAFT JAN 2008 | BS EN 60645-1 - ELECTRO ACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: PURE-TONE AUDIOMETERS |
07/30166205 DC : 0 | BS ISO 389-9 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
I.S. EN ISO 389-9:2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
ANSI/ASA S3.4 : 2007 | PROCEDURE FOR THE COMPUTATION OF LOUDNESS OF STEADY SOUNDS |
ISO 7779:2010 | Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
IEC 60645-1:2017 RLV | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 389-9:2009 | Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
EN ISO 8253-2:2009 | Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test signals (ISO 8253-2:2009) |
EN ISO 389-9:2009 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
BS ISO 532-2:2017 | Acoustics. Methods for calculating loudness Moore-Glasberg method |
ANSI/ASA S12.10 PART 1 : 2010 | ACOUSTICS - MEASUREMENT OF AIRBORNE NOISE EMITTED BY INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS EQUIPMENT - PART 1: DETERMINATION OF SOUND POWER LEVEL AND EMISSION SOUND PRESSURE LEVEL |
ANSI/ASA S3.4 : 2007(R2017) | PROCEDURE FOR THE COMPUTATION OF LOUDNESS OF STEADY SOUNDS |
EN 60645-4:1995 | Audiometers - Part 4: Equipment for extended high-frequency audiometry |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
AS/NZS ISO 8253.2:2019 | Acoustics - Audiometric test methods Sound field audiometry with pure-tone and narrow-band test signals |
IEC 60645-4:1994 | Audiometers - Part 4: Equipment for extended high-frequency audiometry |
ISO 266:1997 | Acoustics — Preferred frequencies |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 389-8:2004 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones |
ISO 389-5:2006 | Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
ISO 389-1:1998 | Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
AS ISO 532.2:2019 | Acoustics - Methods for calculating loudness Moore-Glasberg method |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
AS/NZS ISO 8253.1:2019 | Acoustics - Audiometric test methods Pure-tone air and bone conduction audiometry |
ISO 8253-2:2009 | Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals |
ISO 226:2003 | Acoustics — Normal equal-loudness-level contours |