• ISO 4064-4:2014

    Current The latest, up-to-date edition.

    Water meters for cold potable water and hot water — Part 4: Non-metrological requirements not covered in ISO 4064-1

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English, French

    Published date:  26-05-2014

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 4064-4:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.

    ISO 4064-4:2014 specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand: a) a maximum admissible working pressure (MAP) equal to at least 1 MPa [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm]; b) a maximum admissible temperature (MAT) for cold potable water meters of 30 °C; c) a MAT for hot water meters up to 180 °C, depending on class.

    In addition to meters based on mechanical principles, ISO 4064-4:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/DIS 4064-4. (05/2014)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 14154-4:2014 WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES
    UNI CEI EN ISO 4064-1 : 2014 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS
    ONORM EN 14154-4 : 2015 WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES
    BS EN 60598-2-21:2015 Luminaires Particular requirements. Rope lights
    DIN EN 14154-4:2015-02 Water meters - Part 4: Additional functionalities
    DIN EN ISO 4064-1:2016-09 (Draft) WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014)
    DIN EN 14154-4 E : 2015 WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES
    ISO 20456:2017 Measurement of fluid flow in closed conduits — Guidance for the use of electromagnetic flowmeters for conductive liquids
    BS EN 14154-4:2014 Water meters Additional functionalities
    11/30217192 DC : 0 BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
    15/30317327 DC : 0 BS EN 16941-1 - ON-SITE NON-POTABLE WATER SYSTEMS - PART 1: SYSTEMS FOR THE USE OF RAINWATER
    BS EN ISO 4064-1:2017 Water meters for cold potable water and hot water Metrological and technical requirements
    UNE-EN ISO 4064-1:2015 Water meters for cold potable water and hot water - Part 1: Metrological and technical requirements (ISO 4064-1:2014)
    ISO 4064-1:2014 Water meters for cold potable water and hot water Part 1: Metrological and technical requirements
    UNE-EN 60598-2-21:2015 Luminaires - Part 2-21: Particular requirements - Rope lights
    EN ISO 4064-1:2017 Water meters for cold potable water and hot water - Part 1: Metrological and technical requirements (ISO 4064-1:2014)
    EN 14154-4:2014 Water meters - Part 4: Additional functionalities
    UNE-EN 14154-4:2015 Water meters - Part 4: Additional functionalities
    I.S. EN ISO 4064-1:2017 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014)
    UNI EN 14154-4 : 2015 WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES
    EN 60598-2-21:2015/AC:2017-01 LUMINAIRES - PART 2-21: PARTICULAR REQUIREMENTS - ROPE LIGHTS (IEC 60598-2-21:2014/COR1:2016)
    DIN EN ISO 4064-1:2017-10 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014)

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 7005-2:1988 Metallic flanges — Part 2: Cast iron flanges
    OIML D 11 : 2013 GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS
    ISO 7005-3:1988 Metallic flanges Part 3: Copper alloy and composite flanges
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    OIML R 49-1 : 2013 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS
    ISO 4064-1:2014 Water meters for cold potable water and hot water Part 1: Metrological and technical requirements
    OIML V 1 : 2013 INTERNATIONAL VOCABULARY OF TERMS IN LEGAL METROLOGY (VIML)
    ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective