ISO 52018-1:2017
Current
The latest, up-to-date edition.
Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 1: Overview of options
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
21-06-2017
The set of EPB assessment standards produces a great number of overall and partial EPB indicators as outputs, which can be used for different purposes. ISO 52018-1:2017 deals with the use as requirement of partial EPB indicators related to the fabric and related to the thermal balance of the building. Thermal balance aspects concern both the heating and cooling needs and the free floating temperatures, especially with respect to overheating or too cold indoor temperatures. ISO 52018-1:2017 can support both private parties and public regulators (and all stakeholders involved in the regulatory process) with the "post-processing" of these outputs.
ISO 52018-1:2017 provides standardized tables for reporting, in a structured and transparent manner, the choices that are to be made with respect to the partial EPB requirements covered by ISO 52018-1:2017. The tables are non-restrictive, thus allowing for full regulatory flexibility.
NOTE Table 1 in the Introduction shows the relative position of ISO 52018-1:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
DevelopmentNote |
Supersedes ISO/DIS 52018-1. (06/2017)
|
DocumentType |
Standard
|
Pages |
43
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
UNE-EN ISO 52018-1:2017 | Identical |
DIN EN ISO 52018-1:2018-03 | Identical |
DIN EN ISO 52018-1:2020-10 | Identical |
BS EN ISO 52018-1:2017 | Identical |
NEN EN ISO 52018-1 : 2017 | Identical |
DIN EN ISO 52018-1:2015-08 (Draft) | Identical |
PN EN ISO 52018-1 : 2017 | Identical |
EN ISO 52018-1:2017 | Identical |
I.S. EN ISO 52018-1:2017 | Identical |
ONORM EN ISO 52018-1 : 2018 | Identical |
PNE-EN ISO 52018-1 | Identical |
NS EN ISO 52018-1 : 2017 | Identical |
BS EN ISO 52003-1:2017 | Energy performance of buildings. Indicators, requirements, ratings and certificates General aspects and application to the overall energy performance |
PD CEN ISO/TR 52016-2:2017 | Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Explanation and justification of ISO 52016-1 and ISO 52017-1 |
PD CEN ISO/TR 52003-2:2017 | Energy performance of buildings. Indicators, requirements, ratings and certificates Explanation and justification of ISO 52003-1 |
CEN ISO/TR 52003-2:2017 | Energy performance of buildings - Indicators, requirements, ratings and certificates - Part 2: Explanation and justification of ISO 52003-1 (ISO/TR 52003-2:2017) |
CEN ISO/TR 52016-2:2017 | Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 (ISO/TR 52016-2:2017) |
ISO 52003-1:2017 | Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 1: General aspects and application to the overall energy performance |
S.R. CEN ISO/TR 52003-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - INDICATORS, REQUIREMENTS, RATINGS AND CERTIFICATES - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52003-1 (ISO/TR 52003-2:2017) |
PD CEN ISO/TR 52018-2:2017 | Energy performance of buildings. Indicators for partial EPB requirements related to thermal energy balance and fabric features Explanation and justification of ISO 52018-1 |
S.R. CEN ISO/TR 52016-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52016-1 AND ISO 52017-1 (ISO/TR 52016-2:2017) |
I.S. EN ISO 52003-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - INDICATORS, REQUIREMENTS, RATINGS AND CERTIFICATES - PART 1: GENERAL ASPECTS AND APPLICATION TO THE OVERALL ENERGY PERFORMANCE (ISO 52003-1:2017) |
S.R. CEN ISO/TR 52018-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - INDICATORS FOR PARTIAL EPB REQUIREMENTS RELATED TO THERMAL ENERGY BALANCE AND FABRIC FEATURES - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52018-1 (ISO/TR 52018-2:2017) |
EN ISO 52003-1:2017 | Energy performance of buildings - Indicators, requirements, ratings and certificates - Part 1: General aspects and application to the overall energy performance (ISO 52003-1:2017) |
ISO/TR 52016-2:2017 | Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 |
ISO/TR 52003-2:2017 | Energy performance of buildings Indicators, requirements, ratings and certificates Part 2: Explanation and justification of ISO 52003-1 |
ISO/TR 52018-2:2017 | Energy performance of buildings Indicators for partial EPB requirements related to thermal energy balance and fabric features Part 2: Explanation and justification of ISO 52018-1 |
CEN ISO/TR 52018-2:2017 | Energy performance of buildings - Indicators for partial EPB requirements related to thermal energy balance and fabric features - Part 2: Explanation and justification of ISO 52018-1 (ISO/TR 52018-2:2017) |
ISO 13789:2017 | Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method |
ISO 9972:2015 | Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method |
CEN/TS 16629:2014 | Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards |
EN 15193-1:2017 | Energy performance of buildings - Energy requirements for lighting - Part 1: Specifications, Module M9 |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
ISO 10293:1997 | Glass in building — Determination of steady-state U values (thermal transmittance) of multiple glazing — Heat flow meter method |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
ISO 13788:2012 | Hygrothermal performance of building components and building elements — Internal surface temperature to avoid critical surface humidity and interstitial condensation — Calculation methods |
CEN/TS 16628:2014 | Energy Performance of Buildings - Basic Principles for the set of EPB standards |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
ISO 14438:2002 | Glass in building — Determination of energy balance value — Calculation method |
ISO 52022-3:2017 | Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing |
ISO 18292:2011 | Energy performance of fenestration systems for residential buildings Calculation procedure |
ISO 52016-1:2017 | Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 1: Calculation procedures |
ISO/TR 52018-2:2017 | Energy performance of buildings Indicators for partial EPB requirements related to thermal energy balance and fabric features Part 2: Explanation and justification of ISO 52018-1 |
ISO 15099:2003 | Thermal performance of windows, doors and shading devices — Detailed calculations |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
ISO 52010-1:2017 | Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations |
ISO 52022-1:2017 | Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 1: Simplified calculation method of the solar and daylight characteristics for solar protection devices combined with glazing |
ISO 10291:1994 | Glass in building — Determination of steady-state U values (thermal transmittance) of multiple glazing — Guarded hot plate method |
EN 16798-5-2:2017 | Energy performance of buildings - Ventilation for buildings - Part 5-2: Calculation methods for energy requirements of ventilation systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - Method 2: Distribution and generation |
EN 674:2011 | Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method |
ISO 52003-1:2017 | Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 1: General aspects and application to the overall energy performance |
ISO 9050:2003 | Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors |
ISO 17772-1:2017 | Energy performance of buildings — Indoor environmental quality — Part 1: Indoor environmental input parameters for the design and assessment of energy performance of buildings |
EN 675:2011 | Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method |
ISO/TR 52000-2:2017 | Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1 |
EN 16798-5-1:2017 | Energy performance of buildings - Ventilation for buildings - Part 5-1: Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - Method 1: Distribution and generation |
PREN 16798-1 : DRAFT 2015 | ENERGY PERFORMANCE OF BUILDINGS - PART 1: INDOOR ENVIRONMENTAL INPUT PARAMETERS FOR DESIGN AND ASSESSMENT OF ENERGY PERFORMANCE OF BUILDINGS ADDRESSING INDOOR AIR QUALITY, THERMAL ENVIRONMENT, LIGHTING AND ACOUSTICS - MODULE M1-6 |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
ISO 10292:1994 | Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing |
ISO 14683:2017 | Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.