• ISO 7240-11:2011

    Current The latest, up-to-date edition.

    Fire detection and alarm systems Part 11: Manual call points

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  08-06-2011

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 7240-11:2011 specifies the requirements, test methods and performance criteria for manual call points in fire detection and alarm systems in and around buildings (see ISO 72401). It takes into account indoor and outdoor conditions, the appearance and operation of the manual call points for type A "direct operation" and type B "indirect operation", and covers those which are simple mechanical switches, those which are fitted with simple electronic components (e.g. resistors, diodes) and those which contain active electronic components and which work with the control and indicating equipment for signalling and identifying, for example, an address or location.

    ISO 7240-11:2011 does not cover manual call points for special applications, for example manual call points that are intrinsically safe or for use in hazardous conditions, if such applications require additional or other requirements or tests than those given in ISO 7240-11:2011.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/DIS 7240-11. (06/2011)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    09/30197779 DC : 0 BS ISO 7240-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO TRANSMISSION PATHS
    17/30362102 DC : DRAFT AUG 2017 BS ISO 21927-4 - SMOKE AND HEAT CONTROL SYSTEMS - PART 4: NATURAL SMOKE AND HEAT EXHAUST VENTILATORS; DESIGN, REQUIREMENTS AND INSTALLATION
    12/30249483 DC : 0 BS ISO 7240-14 - FIRE DETECTION AND ALARM SYSTEMS - PART 14: DESIGN, INSTALLATION, COMMISSIONING AND SERVICE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN AND AROUND BUILDINGS
    BS ISO 21927-9:2012 Smoke and heat control systems Specification for control equipment
    ISO 7240-16:2007 Fire detection and alarm systems — Part 16: Sound system control and indicating equipment
    ISO 21927-9:2012 Smoke and heat control systems — Part 9: Specification for control equipment
    IEC 62820-3-2:2018 Building intercom systems - Part 3-2: Application guidelines - Advanced security building intercom systems (ASBIS)
    12/30276319 DC : 0 BS ISO 7240-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 14: DESIGN, INSTALLATION, COMMISSIONING AND SERVICE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN AND AROUND BUILDINGS
    ISO 7240-25:2010 Fire detection and fire alarm systems — Part 25: Components using radio transmission paths

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60068-2-5:2010 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
    EN 894-3:2000+A1:2008 Safety of machinery - Ergonomics requirements for the design of displays and control actuators - Part 3: Control actuators
    IEC 60068-2-18:2017 Environmental testing - Part 2-18: Tests - Test R and guidance: Water
    ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    ISO 7240-2:2003 Fire detection and alarm systems Part 2: Control and indicating equipment
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    ISO 3098-0:1997 Technical product documentation Lettering Part 0: General requirements
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    ISO 3864-1:2011 Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    ISO 7240-1:2014 Fire detection and alarm systems — Part 1: General and definitions
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective