ISO/IEC TR 29158:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Information technology Automatic identification and data capture techniques Direct Part Mark (DPM) Quality Guideline
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-02-2021
English
06-10-2011
ISO/IEC TR 29158:2011 is an engineering document intended for verifier manufacturers and application specification developers.
It describes modifications which are to be considered in conjunction with the symbol quality methodology defined in ISO/IEC 15415 and a symbology specification. It defines alternative illumination conditions, some new terms and parameters, modifications to the measurement and grading of certain parameters, and the reporting of the grading results.
ISO/IEC TR 29158:2011 was developed to assess the symbol quality of direct marked parts, where the mark is applied directly to the surface of the item and the reading device is a two-dimensional imager.
When application specifications allow, this method may also be applied to symbols produced by other methods. This is appropriate when direct part marked (DPM) symbols and non-DPM symbols are being scanned in the same scanning environment. The symbol grade is reported as a DPM grade rather than as an ISO/IEC 15415 grade.
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
PD ISO/IEC TR 29158:2011 | Identical |
NEN NPR ISO/IEC TR 29158 : 2011 | Identical |
16/30344636 DC : 0 | BS EN ISO 11615 - HEALTH INFORMATICS - IDENTIFICATION OF MEDICINAL PRODUCTS - DATA ELEMENTS AND STRUCTURES FOR THE UNIQUE IDENTIFICATION AND EXCHANGE OF REGULATED MEDICINAL PRODUCT INFORMATION |
PD CEN ISO/TS 16791:2015 | Health informatics. Requirements for international machine-readable coding of medicinal product package identifiers |
BS ISO/IEC 18004:2015 | Information technology. Automatic identification and data capture techniques. QR Code bar code symbology specification |
ISO 28219:2017 | Packaging — Labelling and direct product marking with linear bar code and two-dimensional symbols |
ISO/IEC 18004:2015 | Information technology — Automatic identification and data capture techniques — QR Code bar code symbology specification |
15/30281245 DC : 0 | BS ISO 18616-1 - TRANSPORT PACKAGING - REUSABLE, RIGID PLASTICS DISTRIBUTION BOXES - PART 1: GENERAL PURPOSE APPLICATION |
ISO 18616-1:2016 | Transport packaging Reusable, rigid plastic distribution boxes Part 1: General purpose application |
CAN/CSA-ISO/IEC 15415:13 (R2017) | Information technology - Automatic identification and data capture techniques - Bar code symbol print quality test specification - Two-dimensional symbols (Adopted ISO/IEC 15415:2011, second edition, 2011-12-15) |
MIL-STD-130 Revision N:2007 | IDENTIFICATION MARKING OF U.S. MILITARY PROPERTY |
BS PD ISO/TS 16791 : 2014 | HEALTH INFORMATICS - REQUIREMENTS FOR INTERNATIONAL MACHINE-READABLE CODING OF MEDICINAL PRODUCT PACKAGE IDENTIFIERS |
CSA ISO/IEC 15415:2013 | INFORMATION TECHNOLOGY - AUTOMATIC IDENTIFICATION AND DATA CAPTURE TECHNIQUES - BAR CODE SYMBOL PRINT QUALITY TEST SPECIFICATION - TWO-DIMENSIONAL SYMBOLS |
UNE-EN ISO 11615:2013 | Health informatics - Identification of medicinal products - Data elements and structures for the unique identification and exchange of regulated medicinal product information (ISO 11615:2012) |
CEN ISO/TS 16791:2015 | Health informatics - Requirements for international machine-readable coding of medicinal product package identifiers (ISO/TS 16791:2014) |
BS ISO/IEC 15415:2011 | Information technology. Automatic identification and data capture techniques. Bar code symbol print quality test specification. Two-dimensional symbols |
BS ISO 18616-1:2016 | Transport packaging. Reusable, rigid plastic distribution boxes General purpose application |
CAN/CSA-ISO/IEC 18004:16 | Information technology - Automatic identification and data capture techniques - QR code bar code symbology specification (Adopted ISO/IEC 18004:2015, third edition, 2015-02-01) |
ISO/IEC 15415:2011 | Information technology Automatic identification and data capture techniques Bar code symbol print quality test specification Two-dimensional symbols |
BS ISO 28219:2017 | Packaging. Labelling and direct product marking with linear bar code and two-dimensional symbols |
ISO 11615:2017 | Health informatics — Identification of medicinal products — Data elements and structures for the unique identification and exchange of regulated medicinal product information |
ISO/TR 17350:2013 | Direct Marking on Plastic Returnable Transport Items (RTIs) |
S.R. CEN ISO/TS 16791:2015 | HEALTH INFORMATICS - REQUIREMENTS FOR INTERNATIONAL MACHINE-READABLE CODING OF MEDICINAL PRODUCT PACKAGE IDENTIFIERS (ISO/TS 16791:2014) |
ISO/IEC 15416:2016 | Automatic identification and data capture techniques — Bar code print quality test specification — Linear symbols |
ISO/IEC 19762-1:2008 | Information technology Automatic identification and data capture (AIDC) techniques Harmonized vocabulary Part 1: General terms relating to AIDC |
ISO/IEC 19762-2:2008 | Information technology Automatic identification and data capture (AIDC) techniques Harmonized vocabulary Part 2: Optically readable media (ORM) |
ISO/IEC 15415:2011 | Information technology Automatic identification and data capture techniques Bar code symbol print quality test specification Two-dimensional symbols |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.