ISO/TR 22442-4:2010
Current
The latest, up-to-date edition.
Medical devices utilizing animal tissues and their derivatives Part 4: Principles for elimination and/or inactivation of transmissible spongiform encephalopathy (TSE) agents and validation assays for those processes
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
16-11-2010
ISO/TR 22442-4:2010 offers suggestions for designing and conducting validation assays to help determine if processes used in the manufacture of medical devices derived from non-viable animal tissues might serve to reduce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs).
The TSE-removal methods used to process animal tissues should also reduce the risk of transmitting TSE infections via non-viable tissues of human origin; this Technical Report does not address this issue. Some current information on human tissues and TSEs is presented which may be applied by analogy to other animal tissues.
ISO/TR 22442-4:2010 does not intend to imply a need for validation of methods involving specific materials identified as having a "negligible risk" of contamination with TSE agents as listed in Annex C of ISO 22442-1:2007.
It is intended to clarify final draft international standards included in the ISO 22442 series, as well as in ISO 14160.
ISO/TR 22442-4:2010 builds upon the specific discussion in ISO 22442-3 relative to TSE agents and attempts to summarize the current state of the art in the arena of TSE agent elimination. As the understanding of inactivation and elimination of TSE agents evolves, this document will be revised when possible.
DocumentType |
Technical Report
|
Pages |
14
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
PD ISO/TR 22442-4:2010 | Identical |
AAMI/ISO TIR22442-4:2011(R2016) | Identical |
AAMI ISO TIR 22442-4:2011 | Identical |
DIN ISO 13022 E : 2014 | MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES (ISO 13022:2012) |
ISO 5910:2018 | Cardiovascular implants and extracorporeal systems — Cardiac valve repair devices |
DIN ISO 13022:2014-06 | MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES (ISO 13022:2012) |
ISO 13022:2012 | Medical products containing viable human cells — Application of risk management and requirements for processing practices |
ANSI/AAMI/ISO 13022:2012 | MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management |
ISO 22442-2:2015 | Medical devices utilizing animal tissues and their derivatives Part 2: Controls on sourcing, collection and handling |
ISO 22442-3:2007 | Medical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents |
Access your standards online with a subscription