Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

21-07-2015

€92.00
Excluding VAT

ISO/TS 18090-1:2015 is directly applicable to pulsed X-radiation with pulse duration of 0,1 ms up to 10 s. This covers the whole range used in medical diagnostics at the time of publication. Some specifications may also be applicable for much shorter pulses; one example is the air kerma of one pulse. Such a pulse may be produced, e.g. by X-ray flash units or high-intensity femtosecond-lasers. Other specifications are not applicable for much shorter pulses; one example is the time-dependent behaviour of the air kerma rate. This may not be measurable for technical reasons as no suitable instrument is available, e.g. for pulses produced by a femtosecond-laser.

ISO/TS 18090-1:2015 specifies the characteristics of reference pulsed radiation for calibrating and testing radiation protection dosemeters and dose rate meters with respect to their response to pulsed radiation. The radiation characteristics includes the following:

a) time-dependent behaviour of the air kerma rate of the pulse;

b) time-dependent behaviour of the X-ray tube high voltage during the pulse;

c) uniformity of the air kerma rate within a cross-sectional area of the radiation beam;

d) air kerma of one radiation pulse;

e) air kerma rate of the radiation pulse;

f) repetition frequency.

ISO/TS 18090-1:2015 does not define new radiation qualities. Instead, it uses those radiation qualities specified in existing ISO and IEC standards. This part of ISO/TS 18090 gives the link between the parameters for pulsed radiation and the parameters for continuous radiation specifying the radiation qualities. It does not specify specific values or series of values for the pulsed radiation field but specifies only those limits for the relevant pulsed radiation parameters that are required for calibrating dosemeters and dose rate meters and for determining their response depending on the said parameters.

The pulse parameters with respect to the phantom-related quantities were determined using conversion coefficients according to ISO 4037 (all parts). This is possible as the radiation qualities specified in existing ISO and IEC standards are used.

A given reference pulsed X-ray facility is characterized by the parameter ranges over which the full specifications and requirements according to this part of ISO/TS 18090 are met. Therefore, not all reference pulsed X-ray facilities can produce pulses covering the same parameter ranges.

Committee
ISO/TC 85/SC 2
DocumentType
Technical Specification
Pages
17
ProductNote
THIS STANDARD ALSO REFERS TO ICRU 34
PublisherName
International Organization for Standardization
Status
Current

16/30332952 DC : 0 BS ISO 14146 - RADIATION PROTECTION - CRITERIA AND PERFORMANCE LIMITS FOR THE PERIODIC EVALUATION OF DOSIMETRY SERVICES
BS ISO 15382 : 2015 COR 2017 RADIOLOGICAL PROTECTION - PROCEDURES FOR MONITORING THE DOSE TO THE LENS OF THE EYE, THE SKIN AND THE EXTREMITIES
I.S. EN ISO 15382:2017 RADIOLOGICAL PROTECTION - PROCEDURES FOR MONITORING THE DOSE TO THE LENS OF THE EYE, THE SKIN AND THE EXTREMITIES (ISO 15382:2015)
EN ISO 15382:2017 Radiological protection - Procedures for monitoring the dose to the lens of the eye, the skin and the extremities (ISO 15382:2015)
BS EN ISO 15382:2017 Radiological protection. Procedures for monitoring the dose to the lens of the eye, the skin and the extremities
IEC TS 62743:2012 Radiation protection instrumentation - Electronic counting dosemeters for pulsed fields of ionizing radiation
ISO 15382:2015 Radiological protection Procedures for monitoring the dose to the lens of the eye, the skin and the extremities

ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.