JIS A 5308:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Ready-mixed concrete
English
20-12-2003
05-01-2017
This Japanese Industrial Standard specifies the ready-mixed concrete delivered to the point of discharge
| DocumentType |
Standard
|
| Pages |
46
|
| PublisherName |
Japanese Standards Association
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| JIS B 7518:1993 | Vernier, dial and digital depth gauges |
| JIS A 1109:2006 | Methods of test for density and water absorption of fine aggregates |
| JIS A 0203:2006 | Concrete terminology |
| JIS A 1126:2007 | Method of test for content of soft particles in coarse aggregate by scratching |
| JIS A 1144:2001 | Methods of test for chloride concentration in water of fresh concrete |
| JIS A 1143:2001 | Method of test for content of floating particles in lightweight coarse aggregate |
| JIS A 1122:2005 | Method of test for soundness of aggregates by use of sodium sulfate |
| JIS B 7526:1995 | Squares |
| JIS A 1145:2007 | Method of test for alkali-silica reactivity of aggregates by chemical method |
| JIS Z 8801-1:2006 | Test sieves -- Part 1: Test sieves of metal wire cloth Part 1: Test sieves of metal wire cloth |
| JIS A 1102:2006 | Method of test for sieve analysis of aggregates |
| JIS B 7503:1997 | Dial gauges |
| JIS B 7513:1992 | Precision surface plates |
| JIS A 1141:2007 | Method of test for particles less than density of 1.95 g/cm*3 in aggregate |
| JIS A 1119:2005 | Method of test for variability of freshly mixed concrete by measuring mortar and coarse aggregate contents |
| JIS A 1103:2003 | Method of test for amount of material passing test sieve 75 mum in aggregates |
| JIS R 5211:2003 | Portland blast-furnace slag cement |
| JIS A 1142:2007 | Method of test for fine aggregate containing organic impurities by compressive strength of mortar |
| JIS R 5212:1997 | Portland pozzolan cement |
| JIS A 1126:2001 | Method of test for content of soft particles in coarse aggregate by scratching |
| JIS A 1121:2001 | Method of test for resistance to abrasion of coarse aggregate by use of the Los Angeles machine |
| JIS A 1145:2001 | Method of test for alkali-silica reactivity of aggregates by chemical method |
| JIS A 6207:2006 | Silica fume for use in concrete |
| JIS A 1137:2005 | Method of test for clay lumps contained in aggregates |
| JIS A 1104:2006 | Methods of test for bulk density of aggregates and solid content in aggregates |
| JIS A 1116:2005 | Method of test for unit mass and air content of fresh concrete by mass method |
| JIS A 1106:2006 | Method of test for flexural strength of concrete |
| JIS P 3801:1995 | Filter paper (for chemical analysis) |
| JIS A 1105:2001 | Method of test for organic impurities in fine aggregate |
| JIS A 1128:2005 | Method of test for air content of fresh concrete by pressure method |
| JIS A 5011-1:2003 | Slag aggregate for concrete -- Part 1: Blast furnace slag aggregate Part 1: Blast furnace slag aggregate |
| JIS A 1108:2006 | Method of test for compressive strength of concrete |
| JIS A 5002:2003 | Lightweight aggregates for structural concrete |
| JIS A 5011-4:2003 | Slag aggregate for concrete -- Part 4: Electric arc furnace oxidizing slag aggregate Part 4: Electric arc furnace oxidizing slag aggregate |
| JIS A 6201:1999 | Fly ash for use in concrete |
| JIS A 1118:1997 | Method of test for air content of fresh concrete by volumetric method |
| JIS A 1105:2007 | Method of test for organic impurities in fine aggregate |
| JIS B 7507:1993 | Vernier, dial and digital callipers |
| JIS R 5214:2003 | Ecocement |
| JIS A 1142:2001 | Method of test for fine aggregate containing organic impurities by compressive strength of mortar |
| JIS R 5213:1997 | Portland fly-ash cement |
| JIS A 1110:2006 | Methods of test for density and water absorption of coarse aggregates |
| JIS A 6202:1997 | Expansive additive for concrete |
| JIS A 1101:2005 | Method of test for slump of concrete |
| JIS A 5011-3:2003 | Slag aggregate for concrete -- Part 3: Copper slag aggregate |
| JIS A 1121:2007 | Method of test for resistance to abrasion of coarse aggregate by use of the Los Angeles machine |
| JIS A 1150:2007 | Method of test for slump flow of concrete |
| JIS A 1132:2006 | Method of making and curing concrete specimens |
| JIS A 1141:2001 | Method of test for particles less than density of 1.95 g/cm*3 in aggregate |
| JIS A 6206:1997 | Ground granulated blast-furnace slag for concrete |
| JIS A 1134:2006 | Methods of test for particle density and water absorption of lightweight fine aggregates for structural concrete |
| JIS A 1150:2001 | Method of test for slump flow of concrete |
| JIS A 5011-2:2003 | Slag aggregate for concrete -- Part 2: Ferronickel slag aggregate |
| JIS R 5210:2003 | Portland cement |
| JIS A 1146:2007 | Method of test for alkali-silica reactivity of aggregates by mortar-bar method |
| JIS A 1135:2006 | Methods of test for particle density and water absorption of lightweight coarse aggregates for structural concrete |
| JIS A 1143:2007 | Method of test for content of floating particles in light weight coarse aggregate |
| JIS A 1115:2005 | Method of sampling fresh concrete |
| JIS A 1146:2001 | Method of test for alkali-silica reactivity of aggregates by mortar-bar method |
| JIS Q 1011:2005 | Conformity assessment -- Conformity assessment for Japanese Industrial Standards -- Guidance on a third-party certification system for Ready-mixed concrete products |
| JIS E 1202:1997 | Prestressed concrete sleepers -- Post-tensioning type |
| JIS A 8603:1994 | Concrete mixers |
| JIS A 5345:2000 | Reinforced concrete gutters for roadside |
| JIS A 5002:2003 | Lightweight aggregates for structural concrete |
| JIS A 1804:2001 | Methods of test for production control of concrete -- Method of rapid test for identification of alkali reactivity of aggregate |
| JIS A 5412:1995 | Prestressed concrete slab (Double-T type) |
| JIS A 5364:2004 | Precast concrete products -- General rules of materials and product methods |
| JIS E 1201:1997 | Prestressed concrete sleepers -- Pretensioning type |
| JIS A 5023:2006 | Recycled concrete using recycled aggregate Class L |
| JIS A 5011-2:2003 | Slag aggregate for concrete -- Part 2: Ferronickel slag aggregate |
| TR A 0016:2002 | Melt-solidified fine aggregate for concrete derived from municipal solid waste and sewage sludge (Molten slag fine aggregate for concrete) |
| JIS A 5031:2006 | Melt-solidified slag aggregate for concrete derived from municipal solid waste and sewage sludge |
| JIS Q 1012:2005 | Conformity assessment -- Conformity assessment for Japanese Industrial Standards -- Guidance on a third-party certification system for precast concrete products |
| JIS A 5022:2007 | Recycled concrete using recycled aggregate class M |
| TS A 0006:2004 | Concrete using recycled aggregate |
| JIS A 1802:1989 | Methods of test for production control of concrete (Method of test for surface moisture in fine aggregate by centrifugal force) |
| JIS A 1171:2000 | Test methods for polymer-modified mortar |
Access your standards online with a subscription
-