JIS C 8211:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Circuit-breakers for overcurrent protection for household and similar installations
English
20-12-2004
09-03-2022
This Standard specifies a.c. air-break moulded-case circuit-breakers for household and similar installations having a rated voltage not exceeding a.c. 440 V (between lines) or a.c. 300 V (voltage to earth) with a frequency of 50 Hz or 60 Hz, a rated current not exceeding 150 A and a rated breaking capacity not exceeding 25 kA.
| DocumentType |
Standard
|
| Pages |
201
|
| PublisherName |
Japanese Standards Association
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
Reaffirmed 2014 2004(R2014) [20/10/2014]2004(R2009) [01/10/2009]2004 [20/12/2004]99 [20/03/1999]
| JIS C 8201-1:2007 | Low-voltage switchgear and controlgear -- Part 1: General rules |
| JIS C 2134:2007 | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
| JIS C 8269-1:2000 | Low-voltage fuses -- Part 1: General requirements |
| JIS C 8269-11:2000 | Low-voltage fuses -- Part 11: Class A, class B fuses |
| JIS C 0664:2003 | Insulation coordination for low-voltage equipment Part 1: Principles, requirements and tests |
| JIS C 0364-4-473:1999 | Electrical installations of buildings Part 4: Protection for safety Chapter 47: Application of protective measures for safety Section 473: Measures of protection against overcurrent |
| JIS C 3662-6:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 6: Lift cables and cables for flexible connections Part 6: Lift cables and cables for flexible connections |
| JIS C 8201-2-2:2004 | Low-voltage switchgear and controlgear -- Part 2-2: Circuit-breakers incorporating residual current protection Part 2-2: Circuit-breakers incorporating residual current protection |
| JIS C 8269-2-1:2000 | Low-voltage fuses -- Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Section I to V: Examples of types of standardized fuses for use by authorized persions |
| JIS C 3662-1:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements Part 1: General requirements |
| JIS C 3662-2:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 2: Test methods Part 2: Test methods |
| JIS C 0920:2003 | Degrees of protection provided by enclosures (IP Code) |
| JIS C 3662-3:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring |
| JIS C 3662-4:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring |
| JIS C 3662-5:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 5: Flexible cables (cords) |
| JIS C 8222:2004 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) |
| JIS C 8269-2:2000 | Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) |
| JIS C 8201-2-1:2004 | Low-voltage switchgear and controlgear -- Part 2-1: Circuit-breakers |
| JIS C 0364-4-41:1997 | Electrical installations of buildings Part 4: Protection for safety Chapter 41: Protection against electric shock |
| JIS C 60695-2-10:2004 | Fire hazard testing -- Glow-wire apparatus and common test procedure |
| JIS C 3662-7:2003 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 7: Flexible cables screened and unscreened with two or more conductors Part 7: Flexible cables screened and unscreened with two or more conductors |
| JIS C 60364-4-43:2006 | Electrical installations of buildings -- Part 4-43: Protection for safety -- Protection against overcurrent |
| JIS C 5381-1:2004 | Surge protective devices connected to low-voltage power distribution systems -- Performance requirements and testing methods |
| JIS C 8201-2-2:2004 | Low-voltage switchgear and controlgear -- Part 2-2: Circuit-breakers incorporating residual current protection Part 2-2: Circuit-breakers incorporating residual current protection |
| JIS C 8201-2-1:2004 | Low-voltage switchgear and controlgear -- Part 2-1: Circuit-breakers |
| JIS C 8222:2004 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) |
| TR C 0019-413:2000 | Electrical installation guide -- Section 413: Measures of protection against indirect contact by automatic disconnection of supply |
| JIS C 8201-2:1999 | Low-voltage switchgear and controlgear -- Part 2: Circuit breaker |
| JIS B 9960-32:2004 | Safety of machinery -- Electrical equipment of machines -- Part 32: Requirements for hoisting machines Part 32: Requirements for hoisting machines |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.