1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION
Specifies the general requirements for nonestablished reliability (non-ER), established reliability (ER), accurate, wire-wound, fixed resistors that have a maximum resistance tolerance of 1 percent and a high degree of stability with respect to time under specified environmental conditions.
DevelopmentNote |
Supersedes MIL R 39005 (03/2004)
|
DocumentType |
Standard
|
Pages |
78
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
This specification covers the general requirements for nonestablished reliability (non-ER), established reliability (ER), accurate, wirewound, fixed resistors that have a maximum resistance tolerance of 1 percent and a high degree of stability with respect to time under specified environmental conditions. The resistors are capable for continuous full-load (or voltage) operation at any ambient temperature up to 125OC, and when derated, up to 145OC (see 6.5). They are not capable for application where the alternating current (ac) characteristics are of critical importance. ER resistors have life failure rates (FR) ranging from 1.0 percent to 0.001 percent per 1,000 hours (see 1.2.1.5). These FR are established at 60-percent confidence level on the basis of the life tests. The FR, identified by the appropriate symbol, is referred to operation at full rated voltage and temperature.
DSCC 09008 : A | RESISTOR, FIXED, WIREWOUND, (ACCURATE), RADIAL LEADED, 0.1 WATT (RBR81) |
MIL-STD-1580 Revision B:2003 | DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS |
DSCC 15002 : 0 | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.33 WATT (RBR53) |
MIL-PRF-39005-4 Revision G:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR55 |
DSCC 14007 : 0 | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.25 WATT (RBR54) |
MIL-PRF-39005-3 Revision F:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR54 |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
MIL-PRF-39005-10 Revision B:1997 | RESISTORS, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY, AND ESTABLISHED RELIABILITY STYLE RER76 |
DSCC 15003 : 0 | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.15 WATT (RBR55) |
MIL-PRF-39005-1 Revision F:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR52 |
MIL-PRF-39005-9 Revision C:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR75 |
MIL-HDBK-199 Revision D:2018 | Resistors, Selection and Use of |
MIL-DTL-39032 Revision E:2000 | RESISTORS, PACKAGING OF |
MIL-PRF-39005-8 Revision C:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR74 |
MIL-PRF-39005-5 Revision H:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR56 |
MIL-PRF-39005-11 Revision C:2008 | RESISTOR, FIXED, WIRE WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR80 AND RBR81 |
MIL-PRF-39005-2 Revision F:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR53 |
NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
DSCC 15004 : A | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR71) |
DSCC 16001 : 0 | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR75) |
MIL-PRF-39005-7 Revision D:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR57 |
DSCC 14006 : 0 | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.5 WATT (RBR52) |
MIL R 93 : F | RESISTORS, FIXED, WIRE-WOUND (ACCURATE), GENERAL SPECIFICATION FOR |
MIL-PRF-39005-6 Revision F:2008 | RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR71 |
DSCC 14008 : A | RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR56) |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
MIL-STD-202-304 Base Document:2015 | Method 304, Resistance-Temperature Characteristic |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
MIL-STD-202-303 Base Document:2015 | Method 303, DC Resistance |
MIL-STD-202-107 Base Document:2015 | Method 107, Thermal Shock |
MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
MIL-STD-790 Revision G:2011 | Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications |
MIL-STD-202-108 Base Document:2015 | Method 108, Life (at Elevated Ambient Temperature) |
MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.