MIL-PRF-39017 Revision G:2006
Current
The latest, up-to-date edition.
Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, General Specification for
08-02-2006
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION
Specifies the general requirements for nonestablished reliability (non-ER) and established reliability (ER), insulated, film, fixed resistors.
| DevelopmentNote |
Supersedes MIL R 39017 (E) (02/2006)
|
| DocumentType |
Standard
|
| Pages |
170
|
| PublisherName |
US Military Specs/Standards/Handbooks
|
| Status |
Current
|
| Supersedes |
This specification covers the general requirements for nonestablished reliability (non-ER) and established reliability (ER), insulated, film, fixed resistors. These resistors are capable of full load operation at an ambient temperature of 70OC and have a resistance temperature characteristic of 100 parts per million (ppm) and 350 ppm per degree Celsius (ppm/OC). The ER resistors have life failure rate (FR) levels ranging from 1.0 percent to 0.001 percent per 1,000 hours (see 1.2.1.4). These FR levels are established at a 60 percent confidence level on the basis of life tests. Designers are CAUTIONED on using these resistors in high power pulse applications (see 6.13.2).
| MIL-STD-1580 Revision B:2003 | Destructive Physical Analysis for Electronic, Electromagnetic, and Electromechanical Parts |
| MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
| DSCC 98021 : B | RESISTORS, FIXED, FILM (INSULATED), 1/2 WATT |
| DSCC 98022 : B | RESISTORS, FIXED, FILM (INSULATED), 1 WATT |
| MIL-HDBK-199 Revision D:2018 | Resistors, Selection and Use of |
| MIL-DTL-39032 Revision E:2000 | Resistors, Packaging of |
| MIL-PRF-39017-3 Revision H:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR32 |
| DSCC 99011 : B | RESISTORS, FIXED, FILM (INSULATED), 1/4 WATT |
| DSCC 97004 : C | RESISTOR, FIXED, FILM, (INSULATED), 2 WATT |
| MIL-PRF-39017-5 Revision M:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RL505 |
| NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
| DSCC 98020 : B | RESISTORS, FIXED, FILM (INSULATED), 1/8 WATT |
| MIL-PRF-22684 Revision F:2006 | Resistor, Fixed, Film (Insulated) General Specification for |
| MIL-O-52374 Revision E:2013 | Oscillator: High Voltage General Specification for |
| MIL-PRF-39017-1 Revision P:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR07 |
| MIL-PRF-39017-2 Revision K:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR20 |
| MIL-PRF-19207-9 Revision N:2016 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Types FHL18G1 and FHL18G2 |
| MIL-PRF-39017-6 Base Document:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR62 (See Notice 2 for Replacement Information) |
| DSCC 96002 : C | RESISTOR, FIXED, FILM, INSULATED, LOW INDUCTANCE |
| MIL-STD-202-211 Base Document:2015 | Method 211, Terminal Strength |
| MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
| MIL-PRF-39017-5 Revision M:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RL505 |
| MIL-STD-202-304 Base Document:2015 | Method 304, Resistance-Temperature Characteristic |
| MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
| MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
| MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
| MIL-PRF-39017-3 Revision H:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR32 |
| MIL-STD-202-107 Base Document : 2015 | Method 107, Thermal Shock |
| MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
| MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
| MIL-STD-202-215 Base Document:2015 | Method 215, Resistance to Solvents |
| MIL-STD-790 Revision G:2011 | Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications |
| MIL-PRF-39017-1 Revision P:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR07 |
| MIL-STD-202-108 Base Document:2015 | Method 108, Life (at Elevated Ambient Temperature) |
| MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
| MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
| MIL-STD-202 Revision H:2015 | Electronic and Electrical Component Parts |
| MIL-STD-1285 Revision D:2004 | Marking of Electrical and Electronic Parts |
| MIL-PRF-39017-2 Revision K:1997 | Resistor, Fixed, Film (Insulated), Nonestablished Reliability, and Established Reliability, Style RLR20 |
| EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
| MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
| MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
| MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.