MIL-PRF-55514 Revision G:2013
Current
The latest, up-to-date edition.
Capacitor, Fixed, Plastic (or Metallized Plastic) Dielectric, DC or DC-AC, in Nonmetal Cases, Non-Established and Established Reliability General Specification for
06-09-2013
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - QUALIFICATION-SUBMITTAL PLANS
Specifies the general requirements for established reliability (ER) and non-established reliability (non-ER), (product level C), plastic (or metallized plastic) dielectric, fixed capacitors, enclosed in nonmetal cases intended primarily, in view of the limited long term moisture resistant characteristics, for use in potted or encapsulated systems, in blocking, filter, and by-pass applications.
DevelopmentNote |
Supersedes MIL C 55514 (C). (04/2002)
|
DocumentType |
Standard
|
Pages |
57
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
This specification covers the general requirements for established reliability (ER) and non-established reliability (non-ER), (product level C), plastic (or metallized plastic) dielectric, fixed capacitors, enclosed in nonmetal cases intended primarily, in view of the limited long term moisture resistant characteristics, for use in potted or encapsulated systems, in blocking, filter, and by-pass applications (see 6.4). ER capacitors covered by this specification have failure rate levels (M, P, R, and S) ranging from 1.0 percent to 0.001 percent per 1,000 hours. These failure rates (FR) are established at a 90-percent confidence level and maintained at a 10-percent producer’s risk and based on life tests performed at +85°C or +105°C, whichever is applicable. An acceleration factor of 5:1 has been used to relate life test data obtained at 125 percent, or 140 percent of rated voltage at +85°C or +105°C, whichever is applicable, to rated voltage at +85°C or +105°C, whichever is applicable. The product levels are based on catastrophic failures and failures occurring outside the degradation limits.
DSCC 89062 : C | CAPACITOR, FIXED, METALLIZED POLYCARBONATE OR METALLIZED POLYPHENYLENE SULFIDE, NON HERMETICALLY SEALED |
DSCC 09007 : 0 | CAPACITORS, FIXED, METALLIZED PLASTIC DIELECTRIC, DC, IN NONMETAL CASES |
MIL-PRF-55514-7 Revision C:2013 | CAPACITORS, FIXED, METALIZED PLASTIC DIELECTRIC, DC-AC, IN NONMETAL CASES, ESTABLISHED RELIABILITY, STYLE CFR09 |
DSCC 89115 : E | CAPACITORS, FIXED, SURFACE MOUNT, METALLIZED POLYESTER FILM, NONHERMETICALLY SEALED |
MIL-PRF-55514-10 Revision E:2013 | CAPACITORS, FIXED, PLASTIC DIELECTRIC, DC, IN NONMETAL CASES, ESTABLISHED RELIABILITY, STYLE CFR15 |
MIL-PRF-55514-9 Revision C:2013 | CAPACITORS, FIXED, METALLIZED PLASTIC DIELECTRIC, DC, IN NONMETAL CASES, ESTABLISHED RELIABILITY, STYLE CFR13 AND CFR14 |
MIL-HDBK-198 Revision B:2012 | CAPACITORS, SELECTION AND USE OF |
MIL-PRF-55514-13 Revision A:2013 | Capacitor, Fixed, Metalized Plastic Dielectric, DC-AC, in Nonmetal Cases, Established Reliability, Style CFR30 |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
MIL-STD-202-305 Base Document:2015 | Method 305, Capacitance |
MIL-STD-202-107 Base Document:2015 | Method 107, Thermal Shock |
MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
MIL-STD-790 Revision G:2011 | Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications |
MIL-STD-202-104 Base Document:2015 | Method 104, Immersion |
MIL-STD-202-108 Base Document:2015 | Method 108, Life (at Elevated Ambient Temperature) |
MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.