MIL-STD-35-109 Base Document:1976
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
AUTOMATED ENGINEERING DOCUMENT PREPARATION SYSTEM, INDICATORS, POINTER
20-07-2005
1 INTRODUCTION
1.1 Scope
1.2 Purpose
1.3 Format
1.4 Military Specification, Exception Title Index
1.4.1 Title
1.4.2 Index
2 APPLICABLE DOCUMENTS
3 DEFINITIONS
4 GENERAL DESCRIPTION OF AEDS
5 DETAILED DESCRIPTION OF AEDS
5.1 Introduction
5.2 Specification Requirement Sheet (SRS)
5.3 Specification Requirements
5.4 Code 1006 Requirement and Test methods
5.5 Approved Item Code
5.6 Dimensions and Figures
5.7 Applicable Documents
5.8 Tabulation
5.9 Design and Construction
5.9.1 Indicator Scale Range
5.9.2 Indicator Sub Scale Range
5.9.3 Port Configuration
5.9.4 Minimum Zero Adjust From Initial Point
5.9.5 Hermetic Seal
5.9.6 Case
5.9.7 Pointer
5.9.8 Cover Glass
5.9.9 Parallax
5.9.10 Bearings
5.9.11 Lubrication
5.9.12 Filling Media
5.9.13 Electrical Receptacle
5.9.14 Overload Protection
5.9.15 Maximum Weight
5.9.16 Dial Marking
5.9.17 Indicator Input
5.9.18 Indicator Power
5.9.19 Lighting Circuit Voltage
5.10 Acceleration
5.11 Cold Junction Compensator Lag
5.12 Current, Resistance Bulb
5.13 Damping
5.14 DC Resistance
5.15 Dead Spot
5.16 Dielectric Withstanding Voltage at Reduced
Barometric Pressure
5.18 Dielectric Withstanding Voltage at Sea Level
5.19 Dust
5.20 Effect of Lead Length
5.21 Electromagnetic Interference
5.22 Endurance
5.22 Error, Friction
5.23 Error, Pointer Zero Position
5.24 Error, Position
5.25 Error, Scale
5.26 Fogging
5.27 Frequency Cycling
5.28 Fungus
5.29 Helium Test
5.30 Humidity
5.31 Hysteresis
5.32 Immersion
5.33 Indication, Power Off
5.34 Insulation Resistance
5.35 Leakage, Diaphragm Capsule
5.36 Life, Lamp
5.37 Lighting
5.38 Low Liquid Level arming Circuit
5.39 Magnetic Effect
5.40 Mounting Lugs
5.41 Open and Short Circuit
5.42 Operation, Reduced Voltage
5 43 Overpressure
5.44 Overspeed and Reverse
5.45 Power Consumption/Indicator Current
5.46 Press To Test Circuit
5.47 Rain
5.48 Reliability Screening (Burn-In, Aging, Conditioning,
Stabilization, Load Overload)
5.49 Resistance to Soldering Heat
5.50 Response
5.51 Salt Fog
5.52 Seal
5.53 Sensitivity
5.54 Shock
5.55 Solderability
5.56 Starting And Warm up, Low Temperature
5.57 Starting, Room Temperature
5.58 Surge, Voltage
5.59 Temperature - Altitude
5.60 Temperature, High
5.61 Temperature, Low
5.62 Temperature Rise, Indicator
5.63 Terminal, Strength
5.64 Thermal Shock
5.65 Unit Torque Gradient
5.66 Variation, Voltage and Frequency
5.67 Vibration
5.68 Vibration, High Frequency
5.69 Zero, Electrical
5.70 Zero Error At Low Temperature
5.71 Zero Error During Temperature Change
Describes detailed requirements of Indicators, Pointer.
Committee |
AREA - EGDS
|
DevelopmentNote |
NOTICE 3 - Notice of Group Cancellation without replacement. (08/2005)
|
DocumentType |
Standard
|
Pages |
248
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Withdrawn
|
MIL-I-38391 Base Document:1965 | INDICATOR, ELECTRICAL TACHOMETER, ERU-12/A 0-350 RPM (ROTOR), 0-7000 RPM (ENGINE) |
MIL-I-7062 Revision C:1975 | INDICATOR, POSITION, CONTROL SURFACES, 28 VOLT DC, GENERAL SPECIFICATION FOR |
MIL-I-83262 Revision B:1977 | INDICATOR, TEMPERATURE, THERMOCOUPLE HERMETICALLY SEALED, GENERAL SPECIFICATION FOR |
ASTM E 380 : 1993 | Standard Practice for Use of the Internation System of Units (SI) (the Modernized Metric System) (Withdrawn 1997) |
MIL-I-5415 Revision C:1987 | INDICATOR, AIR SPEED, PITOT STATIC PRESSURE GENERAL SPECIFICATION FOR |
MIL I 38135 : B (3) | INDICATOR, INDICATED AIRSPEED AVU 19/A STANDBY |
MIL-I-7070 Revision B:1970 | INDICATOR, TEMPERATURE, ELECTRICAL RESISTANCE, HERMETICALLY SEALED, GENERAL SPECIFICATION FOR |
MIL I 83361 : (4) | INDICATOR, PRESSURE OIL, DUAL EGU-18/A, 0-100 PSI |
MIL-I-26299 Revision G:1990 | INDICATORS, RATE OF FLOW, 0-5,000 PPH, INTEGRALLY LIGHTED |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
MIL-I-7084 Revision A:1988 | INDICATOR, PRESSURE, HYDRAULIC 0-4,000 PSI |
MIL-I-81049 Revision A:1972 | INDICATOR, TEMPERATURE, ELECTRICAL RESISTANCE, VOLTAGE COMPENSATED, MULTIFUNCTION |
MIL-I-6447 Revision C:1974 | INDICATOR, TRUE AIRSPEED TYPE M 1A |
MIL I 8411 : A NOTICE 1 | INDICATOR, AIRFLOW, PRESSURIZED CABIN TYPE A-1 |
MIL-I-81388 Revision A:1971 | INDICATOR REPEATERS, LIQUID OXYGEN QUANTITY |
MIL-I-25437 Revision B:1984 | INDICATORS, AIRCRAFT, PRESSURE, VOLTAGE RATIO TYPE, GENERAL SPECIFICATION FOR |
MIL-L-27160 Revision C:1972 | LIGHTING, INSTRUMENT, INTEGRAL, WHITE GENERAL SPECIFICATION FOR |
MIL-STD-461 Revision G:2015 | REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT |
MIL-I-22054 Revision A:1964 | INDICATOR, PRESSURE, SYNCHRO, DUAL, GENERAL PURPOSE |
MIL-I-25645 Revision D:1970 | INDICATOR, LIQUID OXYGEN QUANTITY, CAPACITANCE TYPE, GENERAL SPECIFICATION FOR |
MIL-I-7071 Revision B:1972 | INDICATOR, TEMPERATURE, THERMOCOUPLE HERMETICALLY SEALED, GENERAL SPECIFICATION FOR |
MIL-I-7721 Revision D:1992 | INDICATOR, VERTICAL SPEED, 3-INCH |
MIL-STD-462 Revision D:1993 | MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-I-81387 Revision A:1971 | INDICATOR, LIQUID OXYGEN QUANTITY |
MIL-I-23832 Revision A:1980 | Indicator, Tachometer, Triple Pointer, Helicopter |
MIL I 7069 : A NOTICE 1 | INDICATORS, TACHOMETER, ELECTRIC, PERCENT SPEED TYPE, AIRCRAFT, GENERAL SPECIFICATION FOR |
MIL-I-22126 Revision B:1972 | INDICATOR, TORQUEMETER, ENGINE, TURBOPROP |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.