NASA KSC STD Z 0013 : 1988
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
POTABLE WATER CROSS-CONNECTION CONTROL DESIGN FOR FACILITIES, STANDARD FOR
15-06-2022
01-01-1988
1.0 Introduction
1.1 Scope
1.2 General
1.3 Basic Goals of KSC Cross-Connection Control
2.0 Applicable Documents
3.0 Definitions
4.0 Requirements
4.1 Application of Devices
4.1.1 Plumbing Fixtures
4.1.2 Water Supply for Fire Systems
4.2 Test Cocks
4.3 Assembly Specifications
4.3.1 Reduced Pressure Principle Backflow
Prevention Assemblies
4.3.2 Double Check Valve Assemblies
4.3.3 Pressure Type Vacuum Breaker Assemblies
4.3.4 Atmospheric Type Vacuum Breaker Assemblies
4.3.5 Hose Connection Vacuum Breaker Assemblies
4.4 Design for Maintenance/Testing
4.4.1 Reduced Pressure Principle
4.4.2 Double Check Valve
4.4.3 Pressure Vacuum Breaker
4.4.4 Atmospheric Vacuum Breaker
4.4.5 Air Gap
4.4.6 Battery (Parallel Installation)
4.5 Design Parameters
4.5.1 Nominal Size
4.5.2 Rated Flow and Allowable Pressure Loss
4.6 Freeze Protection
Provides cross-connection control standards to be used in the design of new facilities and the modification of existing facilities under the design jurisdiction of John F. Kennedy Space Center (KSC).
DocumentType |
Standard
|
PublisherName |
National Aeronautics and Space Administration
|
Status |
Superseded
|
SupersededBy |
ASSE 1001 : 2017 | PERFORMANCE REQUIREMENTS FOR ATMOSPHERIC TYPE VACUUM BREAKERS |
ASSE 1015 : 2011 | PERFORMANCE REQUIREMENTS FOR DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLIES AND DOUBLE CHECK FIRE PROTECTION BACKFLOW PREVENTION ASSEMBLIES |
AWWA C506 : 78(R1983) | BACKFLOW PREVENTION DEVICES - REDUCED PRESSURE PRINCIPLE AND DOUBLE CHECK VALVE TYPES |
ASSE 1011 : 2004 ERRATA 2004 | PERFORMANCE REQUIREMENTS FOR HOSE CONNECTION VACUUM BREAKERS |
AWWA M14 : 3 | RECOMMENDED PRACTICE FOR BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL |
ASSE 1020 : 2004 ERRATA 2008 | PERFORMANCE REQUIREMENTS FOR PRESSURE VACUUM BREAKER ASSEMBLY |
ASSE 1013 : 2011 | PERFORMANCE REQUIREMENTS FOR REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTERS AND REDUCED PRESSURE PRINCIPLE FIRE PROTECTION BACKFLOW PREVENTERS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.