• NBN EN 12981 : 2005 + A1 2009

    Current The latest, up-to-date edition.

    COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Belgian Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    0 Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 List of significant hazards
       4.1 General
       4.2 Mechanical hazards
            4.2.1 Shearing, crushing, cutting, entanglement,
                   drawing-in, impact hazards
            4.2.2 Entrapment hazard
            4.2.3 Personnel's slip, trip and fall hazards
       4.3 Electrical hazards
            4.3.1 Electrical shock (by direct or indirect contact)
            4.3.2 Faulty earthing
            4.3.3 Electromagnetic influences
            4.3.4 Electrostatic phenomena
       4.4 Hazards generated by noise
       4.5 Hazards generated by dangerous substances
            4.5.1 Hazards resulting from contact with coating powder
            4.5.2 Hazards resulting from inhalation of coating powder
       4.6 Fire and explosion hazards
       4.7 Hazards caused by failure of the energy supply and
            malfunction of the control system
    5 Safety requirements and/or protective measures
       5.1 General
       5.2 Mechanical safety requirements
            5.2.1 Safeguarding of danger points
            5.2.2 Protective measures against entrapment
            5.2.3 Protective measures against personnel's slip, trip
                   and fall
            5.2.4 Control system
            5.2.5 Warning devices, indicators, markings and actuating
                   devices
       5.3 Electrical safety requirements
            5.3.1 General
            5.3.2 Protective measures against contact with electrically
                   live parts
            5.3.3 Protective measures regarding earthing
            5.3.4 Protective measures on electromagnetic influences
            5.3.5 Protective measures against electrostatic phenomena
       5.4 Safety requirements and protective measures against noise
       5.5 Safety requirements against dangerous substances
            5.5.1 Protective measures against contact with coating
                   powder
            5.5.2 Protective measures against inhalation of coating
                   powder
       5.6 Safety requirements and protective measures against fire
            and explosion
            5.6.1 Fire
            5.6.2 Explosions
       5.7 Safety requirements and protective measures in case of
            failure of energy supply
    6 Verification of safety requirements and/or protective measures
       6.1 General
       6.2 Verification of the mechanical safety requirements
            6.2.1 General
            6.2.2 Control system
       6.3 Verification of the electrical safety requirements
            6.3.1 Protective measures of contact with live parts
            6.3.2 Protective measures of earthing
            6.3.3 Protective measures against electromagnetic influence
            6.3.4 Protective measures against electrostatic phenomena
       6.4 Verification of the safety requirements and measures
            against noise
       6.5 Verification of requirements against dangerous substances
            6.5.1 Protective measures from contact with coating powder
            6.5.2 Preventive measures of inhalation of coating powder
       6.6 Verification of the safety requirements and protective
            measures against fire and explosion
            6.6.1 Fire
            6.6.2 Explosions
       6.7 Verification of the safety requirements and protective
            measures against failure of energy supply
    7 Information for use
       7.1 General
       7.2 Instruction handbook
            7.2.1 General
            7.2.2 Instructions for use
            7.2.3 Information relating to maintenance
       7.3 Marking
    Annex A (normative) Diagrams relative to hazardous zones
            of potentially explosive atmosphere
    Annex B (normative) Determination of concentration of combustible
            coating powder in terms of LEL
    Annex C (normative) Noise test code
       C.1 General
       C.2 Measurement of sound pressure level at operator's position
            C.2.1 General
            C.2.2 Powder spray booth operating conditions
            C.2.3 Operator's positions
       C.3 Determination of the sound power level
            C.3.1 General
            C.3.2 The greatest dimension of the powder spray booth
                   is less than 7 m
            C.3.3 The greatest dimension of the powder spray booth
                   is equal or more than 7 m
       C.4 Declaration of noise emission values
    Annex D (informative) Diagrams relative to powder spray booths
            classification
    Annex E (informative) Classification of construction material's
            reaction to fire - National standards
    Annex F (informative) References to National Exposure
            Limit Values
    Annex ZA (informative) Relationship between this European Standard
             and the Essential Requirements of EU Directive 98/37/EC
    Bibliography

    Abstract - (Show below) - (Hide below)

    Applies to spray booths for spray application of organic coating powder, referred as "powder spray booths", i.e. machinery and related equipment for automated and/or manual powder coating application processes.

    General Product Information - (Show below) - (Hide below)

    Development Note 2005 Edition Re-issued in August 2009 & incorporates AMD 1 2009. (09/2009)
    Document Type Standard
    Publisher Belgian Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective