INTRODUCTION
1 General
1.1 Scope
1.2 Normative references
2 IEC type designation
2.1 Terms and definitions
3 Common features and isometric view
3.1 Isometric view
3.2 Mating information
4 Cable terminations and internal connections - Fixed and
free connectors
4.1 General
4.2 Termination types
5 Gauges
5.1 Fixed connectors
5.2 Free connectors
6 Characteristics
6.1 General
6.2 Pin and pair grouping assignment
6.3 Classification into climatic category
6.4 Electrical characteristics
6.5 Transmission characteristics
6.6 Mechanical
7 Tests and test schedule
7.1 General
7.2 Arrangement for contact resistance test
7.3 Arrangement for vibration test (test phase CP1)
7.4 Test procedures and measuring methods
7.5 Preconditioning
7.6 Wiring and mounting of specimens
7.7 Test schedules
Annex A (normative) Gauging continuity procedure
A.1 Object
A.2 Preparation of the specimens
A.3 Test method
A.4 Final measurements
A.5 Description of the continuity gauge
Annex B (normative) Locking-device mechanical operation
B.1 Object
B.2 Preparation of the specimens
B.3 Test method
B.4 Final measurements
Annex C (normative) Test-plug requirements
C.1 General
C.2 De-embedding reference NEXT plug construction
C.3 Set-up and calibration
C.4 De-embedding reference plug NEXT measurement
C.5 De-embedding reference NEXT jack construction
C.6 De-embedding reference jack NEXT measurement
C.7 Test plug construction
C.8 Test plug NEXT measurement
C.9 Test plug NEXT requirements
C.10 Connector NEXT testing
C.11 Test plug FEXT loss test procedure - de-embedding
method
C.12 Test plug FEXT loss test procedure - Coaxial
termination method
C.13 Test plug FEXT requirements
C.14 Connector FEXT testing
C.15 Test-plug balance
C.16 Return loss reference plug
C.17 Connector return loss measurement requirements
Annex D (normative) General requirements for the measurement
set-up
D.1 Test instrumentation
D.2 Coaxial cables and test leads for network analysers
D.3 Measurement precautions
D.4 Balun requirements
D.5 Reference components for calibration
D.6 Termination loads for termination of conductor pairs
D.7 Termination of screens
D.8 Test specimen and reference planes
Annex E (normative) Insertion loss
E.1 Object
E.2 Test method
E.3 Test set-up
E.4 Procedure
E.5 Test report
E.6 Accuracy
Annex F (normative) Return loss
F.1 Object
F.2 Test method
F.3 Test set-up
F.4 Procedure
F.5 Test report
F.6 Accuracy
Annex G (normative) Near-end crosstalk
G.1 Object
G.2 Test method
G.3 Test set-up
G.4 Procedure
G.5 Test report
G.6 Accuracy
Annex H (normative) Far-end crosstalk
H.1 Object
H.2 Test method
H.3 Test set-up
H.4 Procedure
H.5 Test report
H.6 Accuracy
Annex I (normative) Transverse Conversion Loss (TCL) and
Transverse Conversion Transfer Loss (TCTL)
I.1 Object
I.2 Test method
I.3 Test set-up
I.4 Procedure
I.5 Test report
I.6 Accuracy
Annex J (normative) Termination of balun
J.1 Termination of balun with low return loss for common mode
Annex K (normative) Gauge requirements
K.1 Fixed connectors
K.2 Free connectors