• NBN EN 61746 : 2006

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    CALIBRATION OF OPTICAL TIME-DOMAIN REFLECTOMETERS (OTDR)

    Available format(s): 

    Superseded date:  01-03-2011

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Belgian Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 General
      1.1 Scope
      1.2 Normative references
    2 Definitions
    3 Calibration test requirements
      3.1 Preparation
      3.2 Test conditions
      3.3 Traceability
    4 Distance calibration - General
      4.1 Location error model
      4.2 Using the calibration results
      4.3 Measuring fibre length
    5 Distance calibration methods
      5.1 External source method
          5.1.1 Short description and advantage
          5.1.2 Equipment
          5.1.3 Measurement procedure
          5.1.4 Calculations and results
          5.1.5 Uncertainties
      5.2 Concatenated fibre method
          5.2.1 Short description and advantages
          5.2.2 Equipment
          5.2.3 Measurement procedures
          5.2.4 Calculations and results
          5.2.5 Uncertainties
      5.3 Recirculating delay line method
          5.3.1 Short description and advantage
          5.3.2 Equipment
          5.3.3 Measurement procedures
          5.3.4 Calculations and results
          5.3.5 Uncertainties
    6 Loss calibration - General
      6.1 Determination of the displayed power level F
      6.2 Selection of an appropriate reference loss A[ref]
      6.3 Development of a test plan
      6.4 Polarization dependence
      6.5 Calculation of the calibration results
      6.6 Using the calibration results
    7 Loss calibration methods
      7.1 Loss calibration with fibre standard
          7.1.1 Short description and advantage
          7.1.2 Equipment
          7.1.3 Measurement procedure
          7.1.4 Calculations and results
          7.1.5 Uncertainties
      7.2 External source method
          7.2.1 Short description and advantage
          7.2.2 Equipment
          7.2.3 Measurement procedure
          7.2.4 Calculations and results
          7.2.5 Uncertainties
      7.3 Splice simulator method
          7.3.1 Short description and advantage
          7.3.2 Equipment
          7.3.3 Procedure
          7.3.4 Calculations and results
          7.3.5 Uncertainties
      7.4 Power reduction method
          7.4.1 Short description and advantage
          7.4.2 Equipment
          7.4.3 Measurement procedure
          7.4.4 Calculations and results
          7.4.5 Uncertainties
    8 Reflectance calibration
    9 Documentation
      9.1 Measurement data and uncertainties
      9.2 Test conditions
    Annex A (normative) Recirculating delay line for distance
                        calibration
                        A.1 Construction
                        A.2 Calibration
                        A.3 Uncertainties
                        A.4 Documentation
    Annex B (normative) Optical fibre standard for loss
                        calibration
                        B.1 Fibre requirements
                        B.2 Suitability check of the fibre
                        B.3 Preparation and calibration of the
                            fibre standard
                        B.4 Recalibration of the optical fibre
                            standard
                        B.5 Uncertainty of the fibre standard
                        B.6 Documentation
    Annex C (normative) Standard splice simulator for loss
                        calibration
                        C.1 Structure
                        C.2 Preparation of the standard splice
                            simulator
                        C.3 Calibration procedure
                        C.4 Uncertainties
                        C.5 Documentation
    Annex D (informative) Mathematical basis
                           D.1 Deviations
                           D.2 Uncertainties type A
                           D.3 Uncertainties type B
                           D.4 Accumulation of uncertainties
                           D.5 Reporting
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications

    Abstract - (Show below) - (Hide below)

    Describes the procedures for calibrating single-mode optical time domain reflectometers (OTDR).

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Belgian Standards
    Status Superseded
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective