NEMA XR 5-1992 (R1999)
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
MEASUREMENT OF DIMENSIONS AND PROPERTIES OF FOCAL SPOTS OF DIAGNOSTIC X-RAY TUBES
03-12-2013
06-12-2012
Foreword
Scope
1 Definitions
2 Slit camera method of measurement
Basic method
Slit camera
Imaging procedure
Photographic technique
Electrical conditions
Measurement of x-ray image
Statement of compliance
3 Focal spot blooming
Exposure factors
Measurement procedure
4 Resolution camera (star pattern) method of evaluation
Basic method
Star pattern camera
Radiographic film
Photographic technique
Electrical conditions
Determination of focal spot resolution
5 Pinhole camera method of evaluation
Introduction
Basic method
Pinhole camera
Photographic technique
Electrical conditions
Method of observation
6 Measurement correlation
Introduction
Basic method
Applicable dimensions
7 Determination of modulation transfer function (MTF)
of the focal spot
General information
Measurement
Calculation of the MTF
Tables
2-1 Test conditions
2-2 Focal spot size tolerance limits (for slit camera
method)
3-1 Test conditions (blooming)
5-1 Pinhole diaphragm dimensions
5-2 ENLARGEMENT FACTOR (E) for pinhole camera
7-1 Standard magnification of MODULATION TRANSFER
FUNCTIONS
Figures
2-1 Slit diaphragm
2-2 Evaluation directions for focal spots
2-3 Amount of contribution to image size due to slit
width
2-4 Imaging geometry
2-5 Determination of ENLARGEMENT FACTOR (E)
2-6 Tube nameplate
4-1 Essential dimensions of the test pattern
4-2 Alignment of the star pattern camera
4-3 Image of the test pattern
5-1 Cross-section of pinhole diaphragm
6-1 Correlation geometry for EFFECTIVE FOCAL SPOT
length determination
6-2 Projection of the ACTUAL FOCAL SPOT over the
radiation field
7-1 Microdensitometer scan
7-2 Limitation of input data
Gives test methods for assessing the properties of focal spots for medical diagnostic x-ray tubes but is not intended for use with x-ray tubes used in computed tomography (CT) scanners.
DocumentType |
Standard
|
PublisherName |
National Electrical Manufacturers Association
|
Status |
Withdrawn
|
NEMA XR 11-1993 (R1999) | TEST STANDARD FOR DETERMINATION OF THE LIMITING SPATIAL RESOLUTION OF X-RAY IMAGE INTENSIFIER SYSTEMS |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.