NEN EN 125 : 2010 + A1 2015
Current
The latest, up-to-date edition.
FLAME SUPERVISION DEVICES FOR GAS BURNING APPLIANCES - THERMOELECTRIC FLAME SUPERVISION DEVICES
12-01-2013
1 General
1.1 Object and field of application
1.2 References
1.3 Definitions
1.4 Classification
1.5 Measuring units
2 Construction requirements
2.1 General construction requirements
2.2 Materials
2.3 Connections
2.4 Seals for glands for moving parts
2.5 Pressure test nipples
2.6 text deleted
2.7 Ignition
3 Performance requirements
3.1 General
3.2 Leak-tightness
3.3 Rated flow rate
3.4 Operating torque and force
3.5 Interlocks
3.6 text deleted
3.7 Closing current
3.8 Torsion and bending
3.9 Durability
3.10 Sealing force
4 Test methods
4.1 General
4.2 Leak-tightness
4.3 Rated flow-rate
4.4 Operating torque and force
4.5 Interlocks
4.6 text deleted
4.7 Measurement of the closing current
4.8 Torsion and bending
4.9 Durability
4.10 Measurement of the sealing force
4.11 Electrical equipment test
5 Marking, installation and operating instructions
5.1 Marking
5.2 Installation, operating and servicing
instructions
5.3 Warning notice
Annexes
A Leak-tightness test - volumetric method
B Leak-tightness test - pressure loss method
C Use of ISO 7-1: 1982 and ISO 228-1: 1982 threads for
connections
D Conversion of pressure loss into leakage rate
E Identification of clauses awhich meet the Essential
Requirements of the Gas Appliance Directive
(90/936/EEC)
Tables
1 Connection sizes
2 Maximum leakage rates
3 Nominal sizes DN and operating torque
4 Torque and bending moment
5 Sequence of testing
6 Tightening torque for flange bolts
Figures
1 Equipment for the flow rate test
2 Electrical circuit for measuring the closing current
3 Arrangement for torsion test
4 Arrangement for bending moment test
5 Paint scratch test apparatus
6 Various types of thermo-electric flame supervision
devices in the de-energized position
7 Various types of thermo-electric flame supervision
devices in the operating and ignition position
8 Apparatus for testing leak-tightness (volumetric
method)
9 Apparatus for testing leak-tightness (pressure loss
method)
Defines the safety, construction and performance requirements for thermoelectric flame supervision devices, energized by a thermocouple intended for use with gas burners, gas appliances and similar use, hereafter referred to as 'controls'.
DevelopmentNote |
2010 Edition Re-Issued in November 2015 & incorporates AMD 1 2015. (01/2016)
|
DocumentType |
Standard
|
PublisherName |
Netherlands Standards
|
Status |
Current
|
Standards | Relationship |
SN EN 125 +A1:2016 | Identical |
UNE-EN 125:2010 | Identical |
ONORM EN 125 : 2016 | Identical |
UNI EN 125 : 2010 | Identical |
EN 125:2010+A1:2015 | Identical |
BS EN 125 : 2010 | Identical |
I.S. EN 125:2010 | Identical |
NF EN 125 : 2010 + A1 2016 | Identical |
DIN EN 125:2016-01 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.