• There are no items in your cart

NEN EN 13384-1 : 2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE

Withdrawn date

01-07-2019

Published date

12-01-2013

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols, terminology and units
5 Calculation method for non-balanced flue chimneys
  5.1 General principles
  5.2 Pressure requirements
  5.3 Temperature requirement
  5.4 Calculation procedure
  5.5 Flue gas data characterizing the heating appliance
  5.6 Characteristic data for the calculation
  5.7 Basic values for the calculation
  5.8 Determination of the temperatures
  5.9 Determination of the density of the flue gas and
       the velocity of the flue gas
  5.10 Determination of the pressures
  5.11 Draught required at the flue gas inlet into the
       chimney (P[Ze]) and maximum differential pressure
       at the flue gas inlet into the chimney (P[Zoe])
  5.12 Calculation of the inner wall temperature at the
       chimney outlet (T[iob])
6 Secondary air for negative pressure chimneys
  6.1 General
  6.2 Calculation method
  6.3 Basic values for the calculation of secondary air
  6.4 Pressures
  6.5 Temperature requirement with secondary air
7 Calculation method for balanced flue chimneys
  7.1 General principles
  7.2 Pressure requirements
  7.3 Temperature requirements
  7.4 Calculation procedure
  7.5 Flue gas data characterizing the heating appliance
  7.6 Characteristic data for the calculation
  7.7 Basic values for the calculation
  7.8 Determination of the temperatures
  7.9 Determination of densities and velocities
  7.10 Determination of pressures
  7.11 Draught required at the flue gas inlet into the
       chimney (P[Ze]) and maximum differential Pressure
       at the flue gas inlet into the chimney (P[Zoe])
  7.12 Calculation of the inner wall temperature at the
       chimney outlet (Ti[ob])
8 Consideration of the condensation heat of the flue gas
  water vapour
  8.1 General
  8.2 Onset of condensation
  8.3 Calculation of the flue gas temperature at the outlet
       of a chimney segment with condensation
       (j greater than or equal to NsegK)
Annex A (informative) Calculation of thermal resistance
Annex B (informative) Tables
Annex C (informative) Chimney outlet with regard to adjacent
        buildings
Annex D (informative) Limit curves of the classification for
        the draught regulator
Annex E (informative) Determination of the gas constant R
        considering the condensation
Bibliography

Defines methods for the calculation of the thermal and fluid dynamic characteristics of chimneys serving one heating appliance.

DocumentType
Standard
PublisherName
Netherlands Standards
Status
Withdrawn
SupersededBy

Standards Relationship
ONORM EN 13384-1 : 2015 Identical
NF EN 13384-1 : 2015 Identical
BS EN 13384-1 : 2002 Identical
DIN EN 13384-1:2015-06 Identical
UNI EN 13384-1 : 2008 Identical
I.S. EN 13384-1:2015 Identical
EN 13384-1:2015 Identical
UNE-EN 13384-1:2016 Identical
NS EN 13384-1 : 2002 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.