THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE

Superseded date

11-10-2012

Published date

23-11-2012

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Terms and definitions, symbols and units
  3.1 Terms and definitions
  3.2 Symbols and units
  3.3 Subscripts
  3.4 Superscripts
4 Geometrical characteristics
  4.1 Main principles
  4.2 Developed areas and internal depth
  4.3 Boundaries of curtain wall structures
      4.3.1 General
      4.3.2 Boundaries of a representative reference element
      4.3.3 Curtain wall areas
5 Cut-off planes and partitioning of thermal zones
  5.1 Rules for thermal modelling
  5.2 Cut-off planes of the geometrical model
6 Calculation of curtain wall transmittance
  6.1 Methodologies
  6.2 Single assessment method
      6.2.1 Thermal transmittance of glazing units and
            panels (filling elements)
      6.2.2 Determination of the heat flow through filling
            element/mullion or transom/filling element
            connection
      6.2.3 Determination of the overall thermal transmittance
            of a curtain wall (U[cw])
  6.3 Component assessment method
      6.3.1 General
      6.3.2 Definition of areas
      6.3.3 Thermal transmittance of glazing units and panels
            (filling elements)
      6.3.4 Thermal transmittance of frames, mullions and transoms
      6.3.5 Linear thermal transmittance
  6.4 Thermal transmittance of a curtain wall built of different
      elements
7 Input data
8 Report
  8.1 Section drawings
  8.2 Overview drawing of the whole curtain wall element
  8.3 Values used for calculation
  8.4 Presentation of results
Annex A (informative) Guidance for calculating the thermal
        transmittance U[cw] of curtain walling using the two methods
Annex B (informative) Linear thermal transmittance of junctions
Annex C (normative) A method for calculating the thermal
        effect of screws using a 2D numerical method and the
        procedures specified in EN ISO 10077-2
    C.1 General
    C.2 Calculation of the equivalent thermal conductivity of
        the screw [lambda][s,eq]
    C.3 Consideration of screw heads and washers
Annex D (normative) Ventilated and unventilated air spaces
Annex E (informative) Component method: Calculation example
    E.1 Data for examples
    E.2 Frames
        E.2.1 Definition and evaluation of areas
        E.2.2 Evaluation of U[f] values
    E.3 Glazing units
        E.3.1 Definition and evaluation of areas
        E.3.2 Evaluation of U[g] values
        E.3.3 Definition of l[g] and evaluation of [psi][g],
              [psi][m,f] and [psi][t,f]
    E.4 Panels
        E.4.1 Definition and evaluation of areas
        E.4.2 Evaluation of U[p] values
        E.4.3 Definition of l[p] and evaluation of the
              [psi][p] values
        E.4.4 Calculation of a complete element
Annex F (informative) Single assessment method: Calculation
        example
    F.1 General description of examples
    F.2 Centre U-value of the glazing unit
    F.3 Centre U-value of the spandrel panel
    F.4 U-values of thermal joints
    F.5 Overall U-value of the curtain wall
Bibliography

Describes a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.

DocumentType
Standard
PublisherName
Netherlands Standards
Status
Superseded

Standards Relationship
I.S. EN 13947:2006 Identical
EN 13947:2006 Identical
DIN EN 13947:2007-03 Identical
BS EN 13947:2006 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.