• NEN EN 483 : 99 AMD 4 2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    GAS-FIRED CENTRAL HEATING BOILERS - TYPE C BOILERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW

    Available format(s): 

    Superseded date:  31-10-2012

    Language(s): 

    Published date:  23-11-2012

    Publisher:  Netherlands Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Definitions
      3.1 Reference conditions
      3.2 Combustible gases
          3.2.1 Test gases
          3.2.2 Reference gas
          3.2.3 Limit gas
          3.2.4 Calorific value
          3.2.5 Relative density
          3.2.6 Wobbe index
          3.2.7 Gas pressures
      3.3 Constituent parts of the boiler
          3.3.1 Gas supply
          3.3.2 Air supply and combustion products evacuation
          3.3.3 Adjusting, control and safety devices
      3.4 Operation of the boiler
          3.4.1 Gas rates
          3.4.2 Outputs
          3.4.3 Useful efficiency
          3.4.4 Gas combustion
          3.4.5 Times
          3.4.6 Spark restoration
          3.4.7 Recycling
          3.4.8 Controlled shutdown
          3.4.9 Safety shutdown
          3.4.10 Locking out
          3.4.11 De-energized to trip principle
          3.4.12 Purge
          3.4.13 Air proving device
          3.4.14 Gas/air ratio control
          3.4.15 Nominal voltage
          3.4.16 Living space dedicated boiler
      3.5 Country of destination
          3.5.1 Direct country of destination
          3.5.2 Indirect country of destination
    4 Classification of boilers
      4.1 Gases and categories
      4.2 Mode of air supply and evacuation of the
          combustion products
          4.2.1 General
          4.2.2 Type of installation of the boiler
          4.2.3 Presence and position of a fan
      4.3 Maximum water-side operating pressure
      4.4 Expansion system
    5 Constructional requirements
      5.1 General
      5.2 Conversion to different gases
      5.3 Materials and thicknesses
          5.3.1 General
          5.3.2 Materials and thickness of sheet metal walls or
                tubes under water pressure for boilers of
                pressure class 3
          5.3.3 Thermal insulation
          5.3.4 Control and safety devices
          5.3.5 Separate combustion products evacuation duct
          5.3.6 Design
      5.4 Method of construction
          5.4.1 Use and servicing
          5.4.2 Connections to the gas and water pipes
          5.4.3 Soundness
          5.4.4 Supply of combustion air and evacuation of the
          5.4.5 Checking the state of operation
          5.4.6 Drainage
          5.4.7 Operational safety in the event of failure of the
                auxiliary energy
     5.5 Electrical equipment
     5.6 Requirements for adjusting, control and
         safety devices
         5.6.1 General
         5.6.2 Adjusters and range-rating devices
         5.6.3 Gas circuit
         5.6.4 Gas governor
         5.6.5 Ignition devices
         5.6.6 Flame supervision devices
         5.6.7 Thermostats and water temperature limiting devices
         5.6.8 Remote control
         5.6.9 Expansion vessel and pressure gauge
     5.7 Burners
     5.8 Pressure test points
    6 Operational requirements
     6.1 General
     6.2 Soundness
         6.2.1 Soundness of the gas circuit
         6.2.2 Soundness of the combustion circuit
         6.2.3 Soundness of the water circuit
     6.3 Heat inputs and heat outputs
         6.3.1 The nominal heat input or the maximum and minimum heat
               input
         6.3.2 Adjustment of the heat input by the downstream gas
               pressure
         6.3.3 Ignition rate
         6.3.4 Nominal output
     6.4 Safety of operation
         6.4.1 Limiting temperatures
         6.4.2 Ignition - Cross lighting - Flame stability
         6.4.3 Reduction of the gas pressure
         6.4.4 Defective closure of the gas valve immediately
               upstream of the main burner
         6.4.5 Pre-purge
         6.4.6 Functioning of a permanent ignition burner when
               the fan stops during the standby time
         6.4.7 Leakage of combustion products for type C[7]
               boilers
     6.5 Adjusting, control and safety devices
         6.5.1 General
         6.5.2 Control devices
         6.5.3 Automatic valves
         6.5.4 Ignition devices
         6.5.5 Flame supervision device
         6.5.6 Gas governor
         6.5.7 Thermostats and water temperature limiting
               devices
         6.5.8 Air proving device
         6.5.9 Functioning of the fan of a type C[4] boiler
     6.6 Combustion
         6.6.1 Carbon monoxide
         6.6.2 Other pollutants
     6.7 Useful efficiencies
         6.7.1 Useful efficiency at the nominal heat input
         6.7.2 Useful efficiency at part load
     6.8 Resistance of the materials to pressure
         6.8.1 General
         6.8.2 Boilers of pressure class 1
         6.8.3 Boilers of pressure class 2
         6.8.4 Boilers of pressure class 3
     6.9 Hydraulic resistance
    7 Test methods
     7.1 General test conditions
         7.1.1 General
         7.1.2 Characteristics of the reference and limit gases
         7.1.3 Installation of the boiler
         7.1.4 Gas circuit
         7.1.5 Conduct of the test to obtain a heat input
         7.1.6 Water circuit
         7.1.7 Thermal equilibrium
         7.1.8 Electrical supply
         7.1.9 Uncertainty of measurements
     7.2 Soundness
         7.2.1 Soundness of the gas circuit
         7.2.2 Soundness of the combustion circuit
         7.2.3 Soundness of the water circuit
     7.3 Heat inputs and heat outputs
         7.3.1 Determination of the nominal heat input or the
               maximum and minimum heat input
         7.3.2 Adjustment of the heat input by the downstream
               pressure
         7.3.3 Ignition rate
         7.3.4 Nominal output
     7.4 Safety of operation
         7.4.1 Limiting temperatures
         7.4.2 Ignition - Cross lighting - Flame stability
         7.4.3 Reduction of the gas pressure
         7.4.4 Defective closure of the gas valve immediately
               upstream of the main burner
         7.4.5 Pre-purge
         7.4.6 Functioning of a permanent ignition burner
               when the fan stops during the standby time
         7.4.7 Leakage of combustion products for type
               C[7] boilers
     7.5 Adjusting, control and safety devices
         7.5.1 General
         7.5.2 Control devices
         7.5.3 Automatic valves
         7.5.4 Ignition devices
         7.5.5 Flame supervision device
         7.5.6 Gas governor
         7.5.7 Thermostats and water temperature limiting devices
         7.5.8 Air proving device
         7.5.9 Functioning of the fan of a type C[4] boiler
     7.6 Combustion
         7.6.1 Carbon monoxide
         7.6.2 Other pollutants
     7.7 Useful efficiencies
         7.7.1 Useful efficiency at the nominal heat input
         7.7.2 Useful efficiency at part load
     7.8 Resistance of the materials to pressure
         7.8.1 General
         7.8.2 Boilers of pressure class 1
         7.8.3 Boilers of pressure class 2
         7.8.4 Boilers of pressure class 3
     7.9 Hydraulic resistance
    8 Marking and instructions
     8.1 Boiler marking
         8.1.1 General
         8.1.2 Data plate
         8.1.3 Supplementary markings
         8.1.4 Packaging
         8.1.5 Warnings on the boiler and the packaging
         8.1.6 Other information
     8.2 Instructions
         8.2.1 Technical instructions
         8.2.2 User's instructions
         8.2.3 Conversion instructions
         8.2.4 Presentation
    Annex A (informative) National situations
    Annex B (informative) Particular national conditions
    Annex C (informative) Classification of Type C boilers
    Annex D (informative) Composition of the gas circuit
    Annex E (informative) Compilation of the test conditions
    Annex F (normative) Test apparatus for Type C2 boilers
    Annex G (informative) Practical method of calibrating the
                          test rig to enable the heat loss Dp
                          to be determined
    Annex H (informative) A-deviations
    Annex J (informative) Main symbols and abbreviations used
    Annex K (informative) Examples for marking
    Annex L (informative) Example of calculation of the
                          weighting factors for a boiler with
                          several rates following Table 17
    Annex M (informative) Calculation of conversions of NOx
    Annex N (informative) Requirements and test methods for
                          separate air supply and combustion
                          products evacuation ducts of Type C6
                          boilers
    Annex ZA (informative) Clauses of this European standard
                           addressing essential requirements
                           or other provisions of EU Directives

    Abstract - (Show below) - (Hide below)

    Defines requirements and test procedures concerned with construction, safety, fitness for purpose and rational energy use, as well as marking and classification of gas-fired central heating boilers fitted with atmospheric burners, fan assisted atmospheric or premixed burners that are hereafter referred to as "boilers".

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Netherlands Standards
    Status Superseded