• NEN EN 50381 : 2004 C1 2006

    Current The latest, up-to-date edition.

    TRANSPORTABLE VENTILATED ROOMS WITH OR WITHOUT AN INTERNAL SOURCE OF RELEASE

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Netherlands Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 Construction requirements for TVR's and ducting
       4.1 General
       4.2 Degree of ingress protection
       4.3 Design and construction
       4.4 Mechanical strength
       4.5 Penetrations
       4.6 Floor drains
       4.7 Floors
       4.8 Doors
       4.9 Inspection window(s)
       4.10 Apertures
       4.11 Enclosures
    5 Requirements for TVR's, equipment group I, type of
       protection vM2
    6 Ventilation requirements for TVR's, equipment group II
    7 Additional ventilation requirements for TVR's with an
       internal source of release
    8 Temperature limits
    9 Minimum safety provisions and devices
    10 Additional safety provisions and devices for TVR's
       meeting the requirements of type of protection v2 and vM2
    11 Additional requirements for TVR's with an internal source
       of release
       11.1 Assessment of containment systems
       11.2 Release conditions
            11.2.1 No release
            11.2.2 Release of a flammable liquid
       11.3 Design requirements for the containment system
            11.3.1 Infallible parts of the containment system
            11.3.2 Containment system with limited release
       11.4 Ignition capable apparatus in the case of type of
            protection v2
       11.5 Location of apparatus in the case of type of
            protection v3
       11.6 Internal hot surfaces
            11.6.1 Loss of minimum pressure differential, type
                   of protection v2
            11.6.2 Loss of ventilation flow, type of protection v2
            11.6.3 Loss of ventilation flow, type of protection v3
       11.7 Potential source of internal release
    12 Requirements for gas detectors
    13 Supply of protective gas
       13.1 Ventilation
       13.2 Leakage Compensation of a Breathable Atmosphere (LCBA)
       13.3 Density limits
    14 Type verification and tests
       14.1 Sequence of tests
       14.2 Thermal tests
       14.3 Overpressure test
       14.4 Purging test
       14.5 Verification of minimum pressure differential
       14.6 Ventilation flow rate tests for TVR's with an internal
            source of release
       14.7 Overpressure test for containment systems with limited
            release
       14.8 Verification of sequence of operation of the safety
            devices
       14.9 Additional tests
    15 Routine tests
       15.1 Test conditions
       15.2 Verification of minimum pressure differential
       15.3 Ventilation flow rate tests for TVR's with an internal
            source of release
       15.4 Overpressure test for containment systems with limited
            release
       15.5 Verification of sequence of operation of the safety
            devices
       15.6 Additional tests
    16 Marking
       16.1 TVR's all cases
       16.2 TVR's with a containment system
       16.3 Safety related control systems
       16.4 Additional marking
    17 Instructions
    Annex A (normative) Method of protection of electrical
            apparatus containing a potential release of a
            flammable gas or vapour
          A.1 Introduction
          A.2 Definitions
          A.3 Requirements
    Annex B (normative) Method of protection of electrical
            apparatus containing a potential release of a
            flammable liquid
          B.1 Introduction
          B.2 Definitions
          B.3 Requirements
          B.4 Flammable non-flashing liquids
          B.5 Spark and particle barriers
          B.6 Flashing liquids
    Annex C (informative) Determination of peak rise in enclosure
            pressure, resulting from an internal release of a
            flashing liquid
          C.1 Introduction
          C.2 Definitions
    Annex D (informative) Method of protection of electrical
            apparatus containing a potential release of a
            flammable gas or vapour
    Annex E (informative) Mathematical model of dilution of a
            source of release
    Bibliography

    Abstract - (Show below) - (Hide below)

    Presents the specific requirements for the construction and testing of transportable ventilated rooms (TVR's), such as skid mounted analyser houses with type of protection 'v' intended for use in potentially explosive atmospheres.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Netherlands Standards
    Status Current