• NF EN 60580 : 2004

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - DOSE AREA PRODUCT METERS

    Available format(s): 

    Superseded date:  01-11-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    AVANT-PROPOS
    INTRODUCTION
    1 Domaine d'application et objet
    2 Références normatives
    3 Terminologie et définitions
    4 Prescriptions générales
      4.1 Prescriptions de performance
      4.2 DOMAINES UTILES minimaux de PRODUIT EXPOSITION-SURFACE
           et de DÉBIT DE PRODUIT EXPOSITION-SURFACE
      4.3 Plan de mesurage
      4.4 VALEURS DE RÉFÉRENCE et les CONDITIONS D'ESSAI
           NORMALISÉES
      4.5 Conditions générales d'essai
           4.5.1 CONDITIONS D'ESSAI NORMALISÉES
           4.5.2 Essai des composants
           4.5.3 TEMPS DE STABILISATION
           4.5.4 Réglages en cours d'essai
           4.5.5 Uniformité du champ de rayonnement
      4.6 Fluctuations statistiques
      4.7 Incertitude de la mesure
      4.8 Règles de construction liées aux performances
           4.8.1 Affichage
           4.8.2 Indication d'un défaut de tension de polarisation
           4.8.3 Dépassement de l'étendue de mesure
           4.8.4 Indication de réinitialisation ou autre état
                 d'inactivité
           4.8.5 CHAMBRE D'IONISATION
      4.9 CONTROLEUR DE CONSTANCE
      4.10 Réglage
      4.11 Sécurité électrique
    5 Limites des CARACTÉRISTIQUES DE PERFORMANCE SOUS CONDITIONS
      D'ESSAI NORMALISÉES
      5.1 ERREUR INTRINSEQUE RELATIVE
      5.2 Fonction d'alarme
      5.3 Répétabilité
      5.4 POUVOIR DE RÉSOLUTION de lecture
      5.5 TEMPS DE STABILISATION
      5.6 Réinitialisation des plages de PRODUIT EXPOSITION-SURFACE
      5.7 Dérive des VALEUR INDIQUÉES
      5.8 Stabilité à long terme
      5.9 TEMPS DE RÉPONSE
      5.10 Uniformité spatiale de la RÉPONSE
    6 LIMITES DE VARIATION pour les effets des GRANDEURS D'INFLUENCE
      6.1 Dépendance de l'énergie de la RÉPONSE
      6.2 Dépendance des mesures de PRODUIT EXPOSITION-SURFACE du
           DÉBIT DE PRODUIT EXPOSITION-SURFACE
           6.2.1 ENSEMBLE DE MESURAGE
           6.2.2 CHAMBRE D'IONISATION - pertes de recombinaison
      6.3 DURÉE D'IRRADIATION
      6.4 Taille du champ
      6.5 Tension de fonctionnement
      6.6 Pression d'air
      6.7 Température et humidité
      6.8 Fluctuation de la densité de l'air dans la CHAMBRE
           D'IONISATION
      6.9 Compatibilité électromagnétique
           6.9.1 Généralités
           6.9.2 Décharges électrostatiques
           6.9.3 Champs électromagnétiques rayonnés
           6.9.4 Perturbations conduites induites par les salves
                 et les hautes fréquences
           6.9.5 Ondes de choc
           6.9.6 Creux de tension, coupures brèves et VARIATIONS
                 de tension
      6.10 INCERTITUDE NORMALE COMBINÉE
    7 Marquage
      7.1 ENSEMBLE DE MESURAGE
      7.2 CHAMBRE D'IONISATION
    8 DOCUMENTS D'ACCOMPAGNEMENT
    Bibliographie
    Index des termes définis
    Annexe ZA (normative) Références normatives à d'autres
                          publications internationales avec les
                          publications européennes correspondantes

    Abstract - (Show below) - (Hide below)

    Defines performance and testing of DOSE AREA PRODUCT METERS with IONIZATION CHAMBERS for measurement of DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. Objectives are to: establish criteria for a satisfactory performance level for DOSE AREA PRODUCT METERS, and standardize the methods for determining compliance with this level of performance.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C74-103. PR NF NF EN 60580 December 2003. (12/2003)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN 60601-2-54 : 2009 AMD 1 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY

    Standards Referencing This Book - (Show below) - (Hide below)

    NF EN 61187 : 1995 ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 60731:2011+AMD1:2016 CSV Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy
    IEC 60950:1999 Safety of information technology equipment
    IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
    NF EN 61000 4-2 : 2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-2: TESTING AND MEASUREMENT TECHNIQUES - ELECTROSTATIC DISCHARGE IMMUNITY TEST
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    NF EN 61000-4-4 : 2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    NFC 74 000 : 1989 MEDICAL RADIOLOGY - TERMINOLOGY
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    NF EN 60601-1-2 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    NF EN 60731 : 2012 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY
    NF EN 61000 4-6 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    HD 501 : 200S1 MEDICAL RADIOLOGY - TERMINOLOGY
    NF EN 61000-4-11 : 2004 AMD 1 2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS
    IEC 60601-1-1:2000 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective