• NF EN 61048 : 2006 AMD 1 2016

    Current The latest, up-to-date edition.

    AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    AVANT-PROPOS
    INTRODUCTION
    1 Domaine d'application
    2 Références normatives
    3 Termes et définitions
    4 Prescriptions générales
    5 Généralités sur les essais
    6 Marquage
       6.1 Marquage obligatoire
       6.2 Informations supplémentaires
       6.3 Durabilité et lisibilité du marquage
    7 Moyens de raccordement
    8 Lignes de fuite et distances dans l'air
    9 Tension assignée
    10 Fusibles
    11 Résistances de décharge
    12 Ordre des essais
    13 Essai de scellement et d'échauffement
       13.1 Essai de scellement et d'échauffement pour les
            condensateurs de type A
       13.2 Essai de scellement et d'échauffement pour les
            condensateurs de type B
    14 Essai sous tension élevée
       14.1 Essai sous tension élevée entre bornes
       14.2 Essai sous tension élevée entre bornes et boîtier
    15 Résistance aux conditions de fonctionnement
       défavorables
       15.1 Essai à l'humidité sous tension
       15.2 Essai en courant (décharge)
    16 Résistance à la chaleur, au feu et au cheminement
       16.3 Essai de cheminement
    17 Essai d'autorégénération
    18 Essai de destruction
       18.1 Essai A
       18.2 Essai B
       18.3 Condensateurs non autorégénérateurs
    Annexe A (normative) Tension d'essai
    Annexe B (normative) Réglage de la température de
              l'enceinte d'essai
    Annexe C (normative) Essai de conformité de production
    Annexe D (informative) Guide de calcul des réglages de
              l'équipement pour les essais des paragraphes
              15.2 et 18.1.3
    Annexe ZA (normative) Références normatives à d'autres
              publications internationales avec les
              publications européennes correspondantes
    Bibliographie

    Abstract - (Show below) - (Hide below)

    States the requirements for self-healing and non-self-healing continuously rated a.c. capacitors (having a rated voltage not exceeding 1,000 V) that are meant for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3,000 m. Covers capacitors meant for connection in shunt or in series with the lamp circuit or an effective combination of these. Does not cover radio- interference suppressor capacitors.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes NFC 71 215 PR NF EN 61048 November 2001. (11/2001) Indice de classement: C71-242 Supersedes NFC 71 242 (05/2005)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN 60931-1 : 97 AMD 1 2003 SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
    NF EN 60831-1 : 2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION

    Standards Referencing This Book - (Show below) - (Hide below)

    NF EN 61049 : 1993 CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PERFORMANCE REQUIREMENTS
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    NF EN 60529 : 92 AMD 2 2014 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
    IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
    NF EN 60598-1 : 2015 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
    NF EN 60695-11-5 : 2017 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
    ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
    NF EN 60695-2-11 : 2014 FIRE HAZARD TESTING - PART 2-11: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END-PRODUCTS (GWEPT)
    IEC 60695-11-5 : 2.0 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective