NF EN 62153-1-1 : 2004
Current
The latest, up-to-date edition.
METALLIC COMMUNICATION CABLES TEST METHODS - PART 1-1: ELECTRICAL - MEASUREMENT OF THE PULSE/STEP RETURN LOSS IN THE FREQUENCY DOMAIN USING THE INVERSE DISCRETE FOURIER TRANSFORMATION (IDFT)
12-01-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement principle
5 Performance calculations
6 Procedure
6.1 Coaxial cables
6.1.1 Equipment
6.1.2 Preparation of test specimen
6.1.3 Calibration
6.1.4 Attenuation constant
6.2 Balanced cables
7 Expression of results
8 Requirements
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Specifies the test which determines the regularity of impedance of r.f. cables by measuring the return loss in the frequency domain using a vector network analyser equipped with a reflection test set (bridge) and transferring the results into the time domain by using the Inverse Discrete Fourier Transformation (IDFT).
DevelopmentNote |
Indice de classement: C90-133-1-1. (05/2004)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Standards | Relationship |
BS EN 62153-1-1:2004 | Identical |
EN 62153-1-1:2004 | Identical |
DIN EN 62153-1-1:2004-09 | Identical |
IEC 62153-1-1:2003 | Identical |
I.S. EN 62153-1-1:2004 | Identical |
NF EN 50117-2-1 : 2005 AMD 2 2016 | COAXIAL CABLES - PART 2-1: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
NF EN 50117-4-1 : 2008 AMD 1 2013 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
NF EN 50117-2-3 : 2005 AMD 2 2016 | COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
NF EN 50117-2-2 : 2005 AMD 2 2016 | COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
NF EN 50117-2-4 : 2005 AMD 2 2016 | COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
NF EN 50117-2-5 : 2005 AMD 2 2016 | COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.