• NF EN ISO 15877-2 : 2009 AMD 1 2011

    Current The latest, up-to-date edition.

    PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 2: PIPES

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Avant-propos
    Introduction
    1 Domaine d'application
    2 Références normatives
    3 Termes et définitions, symboles et abréviations
    4 Matière
       4.1 Généralités
       4.2 Matière des tubes
       4.3 Évaluation des valeurs sigma[LCL]
       4.4 Influence sur l'eau destinée à la consommation
            humaine
    5 Caractéristiques générales
       5.1 Aspect
       5.2 Chanfreinage
       5.3 Opacité
    6 Caractéristiques géométriques
       6.1 Généralités
       6.2 Dimensions des tubes
            6.2.1 Diamètres extérieurs
            6.2.2 Épaisseurs de paroi et tolérances
            6.2.3 Longueur des tubes
            6.2.4 Tubes à emboîtures
    7 Caractéristiques mécaniques
       7.1 Résistance à la pression interne
       7.2 Résistance au choc
       7.3 Résistance à la traction
    8 Caractéristiques physiques
    9 Exigences d'aptitude à l'emploi
    10 Colles
    11 Marquage
       11.1 Généralités
       11.2 Marquage minimal exigé
       11.3 Marquage supplémentaire
    Annexe A (informative) Détermination de la valeur maximale
                           calculée de la série du tube S[calc,max]
       A.1 Généralités
       A.2 Contrainte de dimensionnement
       A.3 Détermination de la valeur maximale de S[calc]
            (S[calc,max])
       A.4 Utilisation de S[calc], max dans la détermination de
            l'épaisseur de paroi
    Bibliographie

    Abstract - (Show below) - (Hide below)

    Specifies the requirements of pipes made from chlorinated poly(vinyl chloride) (PVC-C) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), under design pressures and temperatures appropriate to the class of application.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: T54-014-2. PR NF EN ISO 15877-2 September 2006. (09/2006) Supersedes NFT 54 014-2. (01/2011)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN ISO 21003-2 : 2008 AMD 1 2011 MULTILAYER PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS INSIDE BUILDINGS - PART 2: PIPES
    NF EN ISO 21003-1 : 2008 MULTILAYER PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS INSIDE BUILDINGS - PART 1: GENERAL
    NF EN ISO 15877-3 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 3: FITTINGS
    NF EN ISO/TS 15877-7 : 2004 XP PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
    NF EN ISO 15877-5 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM

    Standards Referencing This Book - (Show below) - (Hide below)

    NF EN ISO 15877-3 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 3: FITTINGS
    ISO 6259-2:1997 Thermoplastics pipes Determination of tensile properties Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI)
    NF EN ISO 7686 : 2005 PLASTICS PIPES AND FITTINGS - DETERMINATION OF OPACITY
    NF EN ISO 2505 : 2005 THERMOPLASTICS PIPES - LONGITUDINAL REVERSION - TEST METHOD AND PARAMETERS
    NF EN 744 : 1995 PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES - TEST METHOD FOR RESISTANCE TO EXTERNAL BLOWS BY THE ROUND-THE-CLOCK METHOD
    NF EN ISO 15877-1 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 1: GENERAL
    NF EN ISO 6259-1 : 2015 THERMOPLASTICS PIPES - DETERMINATION OF TENSILE PROPERTIES - PART 1: GENERAL TEST METHOD
    NF EN ISO 3126 : 2005 PLASTICS PIPING SYSTEMS - PLASTICS COMPONENTS - MEASUREMENT OF DIMENSIONS
    NF EN ISO 1167-1 : 2006 THERMOPLASTICS PIPES, FITTINGS AND ASSEMBLIES FOR THE CONVEYANCE OF FLUIDS - DETERMINATION OF RESISTANCE TO INTERNAL PRESSURE - PART 1: GENERAL METHOD
    NF EN ISO 9080 : 2012 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION
    NF EN ISO 1167-2 : 2006 THERMOPLASTICS PIPES, FITTINGS AND ASSEMBLIES FOR THE CONVEYANCE OF FLUIDS - DETERMINATION OF THE RESISTANCE TO INTERNAL PRESSURE - PART 2: PREPARATION OF PIPE TEST PIECES
    NF EN 727 : 1994 PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES AND FITTINGS - DETERMINATION OF VICAT SOFTENING TEMPERATURE (VST)
    NF EN ISO 15877-5 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective