• NFC 33 002 : 98 AMD 1 2003

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - ACCESSORIES OF DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 (1,2) KV - TEST METHODS AND REQUIREMENTS

    Available format(s): 

    Superseded date:  01-09-2010

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Domaine d'application
    2 Références normatives
    3 Définitions
    4 Caractéristiques électriques
      4.1 Tension assignée
      4.2 Intensités admissibles
    5 Acceptation de type
      5.1 Généralités
      5.2 Jonctions, dérivations et bouts perdus
      5.3 Jonctions de transition
      5.4 Essais facultatifs
    6 Essais de type
      6.1 Généralités
      6.2 Échantillons pour les essais
      6.3 Séquence d'essais
      6.4 Conditions d'essais
      6.5 Fréquence et forme d'onde des tensions d'essai à
          fréquence industrielle
      6.6 Spécifications d'essai
          6.6.1 Détermination de la température du câble
          6.6.2 Stabilité thermique
          6.6.3 Tension de choc à la température ambiante
          6.6.4 Tenue sous tension alternative
          6.6.5 Choc mécanique à basse température
          6.6.6 Choc mécanique à la température ambiante
          6.6.7 Mesure de la résistance d'isolement
          6.6.8 Cycles thermiques
          6.6.9 Pénétration d'eau
          6.6.10 Tenue de l'écran métallique au court-circuit
          6.6.11 Essai d'immersion
          6.6.12 Examen
    7 Marquage, étiquetage, conditionnement et informations à donner
      par le fabricant
    Annexe A (informative) Détermination de la température de l'âme
                            du câble
    Annexe B (normative) Marquage, étiquetage, conditionnement et
                            informations à donner par le fabricant
    Annexe NA (normative) Exigences particulières relatives à
                            l'utilisation des accessoires 0,6/1 kV
                            sur les réseaux de distribution publique
                            français

    Abstract - (Show below) - (Hide below)

    Ce document définit les essais applicables aux accessoires de câbles souterrains de distribution couverts par le document d'harmonisation HD 603 S1. Il s'applique plus particulièrement aux accessoires destinés au câble conforme à la norme NF C 33-210 (HD 603, Partie 5-F). Il définit également les exigences particulières relatives à l'utilisation des accessoires sur les réseaux de distribution publique français.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C33-002. (01/2004)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFC 32 902 : 1998 INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS

    Standards Referencing This Book - (Show below) - (Hide below)

    UTEC 33 013 : 1993 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - PARTICULAR REQUIREMENTS FOR THE USE OF SELF-AMALGAMATING TAPES AND POLYMERISABLE FILLING COMPOUNDS ON FRENCH POWER SYSTEMS
    NF EN 61180-1 : 1995 HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 1: DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS
    NFC 33 010 : 93 XP INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - FILLING COMPOUNDS POLYMERISABLE AT AMBIENT TEMPERATURE, CAST OR INJECTED FOR CABLE ACCESSORIES OF RATED VOLTAGES UP TO AND INCLUDING 12/20(24) KV
    XP C20 540 : 2002 XP ENVIRONMENTAL TESTING - TEST METHODS - CLIMATIC AGEING TEST OF EQUIPMENT AND SYNTHETIC MATERIALS FOR OUTDOOR USE
    NFC 33 210 : 1995 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - CROSS-LINKED POLYETHYLENE INSULATED CABLES COVERED WITH A POLYVINYL CHLORIDE SHEATH - TYPE H1 XDV-A
    HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
    NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    NFC 33 090-1 : 95 XP COMPRESSION CONNECTORS FOR INSULATED CABLES - PART 1: DEEP STEPPED INDENT CONTROLLED VOLUME COMPRESSION OF ALUMINIUM CONDUCTORS
    NFC 33 100 : 65 AMD 1 1967 INSULATED CONDUCTORS FOR POWER SYSTEMS - IMPREGNATED PAPER INSULATED LEAD-SHEATHED CABLES
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    NFC 33 090-4 : 99 XP INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - COMPRESSION CONNECTORS FOR INSULATED CABLES - PART 4: TOOLS AND TOOLING
    NFC 63 213 : 2005 LOW-VOLTAGE FUSES - PART 2-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - SECTIONS 1 TO 6: EXAMPLES OF TYPES OF STANDARDIZED FUSES
    NF EN 60811 1-4 : 96 AMD 2 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 4: TEST AT LOW TEMPERATURE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective